3.6 Setting DIP Switch

The DIP switch is present on the serial interface board.

The function of each switch is as shown below.

DIP switch

Interface board mounting screws

CAUTION!

As for the setting of the serial interface, it gives priority to the setting of the memory switch rather than the DIP switch as the factory default.

Consult with the dealer where the printer was purchased when the change of the DIP switch setting is necessary.

Switch No.

Function

ON

 

OFF

Initial

 

Settings

 

 

 

 

 

 

1

Communication condition

DIP switch setting

Memory switch

OFF

 

setting method

 

 

setting

 

2

Hand shake

XON/XOFF

DTR/DSR

OFF

3

Bit length

7 bits

8 bits

OFF

4

Parity check

With parity

None

OFF

5

Parity selection

Even parity

Odd parity

OFF

6

 

 

 

 

 

OFF

Baud rate selection

See Table below.

 

 

 

7

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

8

INIT

Reset

Invalid

OFF

Selecting baud rate

 

 

 

 

 

Baud Rate (bps)

 

Switch No.

6

 

7

 

 

2400

OFF

 

OFF

4800

ON

 

OFF

9600

OFF

 

ON

19200

ON

 

ON

38400, 57600 and 115200 bps can also be selected by a command, etc.

— 19 —