iDP-3540/41 User’s Manual
CITIZEN 32/48
2) RS-422A type only
No. Function OFF ON Factory
Setting
1 2 LHOFF
2 2 Printer address LHOFF
3 2 LHOFF
4 - OFF
5OFF
6Baud rate setting Refer to the table below ON
7ON
8OFF
bps 110 150 300 600 1200 2400 4800 9600
No.
5OFF ON OFF ON OFF ON OFF ON
6OFF OFF ON ON OFF OFF ON ON
7OFF OFF OFF OFF ON ON ON ON
8OFF OFF OFF OFF OFF OFF OFF OFF
11-3. Slide Switch Setting (Serial interface specifications only)
RS-232C or 20mA current loop can selected by changing slide switch SW1 on the control board.
The side labeled “RS” is for RS-232C and the side labeled “CL” is for 20mA current loop.
The switch is set at the factor for RS-232C.
11-4. Dip-Switch Location
Power off and remove the printer cover before setting the Dip-Switches.
Notes: DS2 is mounted for Serial type and RS-422A type only.