Each compartment has capacity for: | ||
• | Three, 12˝ x 2 0˝ x 2 | 1⁄2˝ or six, 12˝ x 2 0˝ x 1 ˝ dee p |
Cafeteria Pans. |
|
| |
WATER QUALITY REQUIREMENT | |
The r ecommended minimum water q uality s tandards | |
whether untreated or | |
of use per day, and a Daily Blowdown, are as follows: | |
TOTAL DISSOLVED SOLIDS | less than 60 parts per million |
TOTAL ALKALINITY | less than 20 parts per million |
SILICA | less than 13 parts per million |
pH FACTOR | greater than 7.5 |
CHLORINE | less than 30 parts per million |
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use o f h ighly mineralized wa ter wi ll me an t hat m ore frequent servicing of the steam generator will be neces- sary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
**Do not connect to GFI outlet. See note below.
1 1/2” IPS common drain. Do not connect other units to this drain.
Do not use PVC pipe for drain.
Right - 6”, Left - 6”, Rear - 6” (12” on control side if adjoining wall or equipment is over 30” high for service acess)
For use in non- combustible locations. Contact factory for variances to clearances
NOTES:
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibil ity of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are A SME/N. Bd, UL, NSF and CSA (AGA, CGA).