Cleveland Range 42-CKGM-300, 42-CKGM-200 specifications Water Quality Requirement

Models: 42-CKGM-200 42-CKGM-300

1 2
Download 2 pages 61.32 Kb
Page 2
Image 2
WATER QUALITY REQUIREMENT

ACTUAL CAPACITIES:

Kettle 6 gallons/23 liters or 192, 4 oz. servings.

• Other size servings may be calculated. Each compartment has capacity for:

• Three, 12˝ x 20˝ x 21⁄ ˝ or six, 12˝ x 20˝ x 1˝ deep Cafeteria Pans. 2

WATER QUALITY REQUIREMENT

The recommended minimum water quality stan-

dards whether untreated or p re-treated, ba sed

upon 10 hours o f u se per da y, a nd a Daily

Blowdown, are as follows:

TOTAL DISSOLVED

less than 60 parts per million

SOLIDS

TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that m ore f requent ser vicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.

5.0 Amps

** Do not connect to GFI outlet. See note below.

1 1/2” IPS common drain. Do not connect other units to this drain.

Do not use PVC pipe for drain.

Right - 6”, Left - 6”, Rear - 6” (12” on control side if adjoining wall or equipment is over 30” high for service access)

For use in non- combustible locations. Contact factory for variances to clearances

NOTES:

**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM. Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibil ity of the owner and installer to comply with the codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are A SME/N. Bd, NSF and CSA (AGA, CGA).

(NOTIII TO SCALE)20

SECT. PAGE1007

Litho in U.S.A

Page 2