Cleveland
CLASSIC CONVECTION STEAMERS 15 PSI BOILER BASE STYLE
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
Cleveland Classic Series CONVECTION
STEAMERS
TWO COMPARTMENT, PRESSURELESS, PLUS ONE 6 GALLON KETTLE, 200, 300M BTU GAS FIRED STEAM GENERATOR
42” WIDE CABINET BASE DESIGN, with NICKELGUARD™
Cleveland Standard Features
|
| |
■ | Cooking Capacity for up to six 12˝ x 20˝ x 21⁄2˝ deep Cafeteria Pans. | |
■ | Pressureless cooking with forced convection steam, permitting | |
■ | doors to be opened while cooking continues. | |
Solid State Controls operate water level and safety functions. | ||
■ | Each compartment is equipped with a 60 minute mechanical | |
| timer, separate bypass switch for constant steaming and a cold | |
| water condenser for superior cooking results. | |
■ Instant Steam Standby Mode: Holds generator at steaming | ||
| temperature. Allows unit to start cooking instantly. | |
■ Durable 14 Gauge Stainless Steel Construction: | ||
■ | For Compartment Door and Steam Cooking Cavity. | |
Separate Main Power Switch for “On/Off” | ||
■ | Exclusive Steam Cooking Distribution System: The exclusive | |
| Convection Jets producea high velocity convection steam without | |
| fans. Coved Corner design in cooking compartment distributes heat | |
| evenly and is easy to keep clean. Creased top & bottom enhance | |
| drainage. Cold Water Condenser for each compartment maintains a | |
| dry steam. Fully insulated cooking compartment forthermal efficiency. | |
| Removable StainlessSteel Slide Racks for easy cleaning. | |
■ Exclusive “Cool to the Touch” Compartment Door Design: | ||
| Free floating inner door with reversible door gasket provides an | |
| air tight seal. Stainless Steel Slam/Latch Door Latch mechanism | |
| provides greater reliability. | |
■ Left Hand Door Hinging: Compartment Doors hinged left, | ||
■ | controls on the right. | |
Modular Cabinet Base with Hinged Door. | ||
■ | High Efficiency Gas Steam Generator with Electronic Spark | |
| Ignition and Automatic Water Fill on start up. | |
■ Automatic Generator Drain at shutdown: Large 3⁄4˝ drain valve | ||
| contains a “Water Jet” Spray Rinse Cleaning Cycle to keep drain clear. | |
■ Automatic Water Level Control System with Low Water | ||
| Power | |
■ Steam generator equipped with High Limit Pressure Safety Switch, | ||
| 15 psi Safety Valve, and Steam Generator Pressure Gauge. | |
■ NSF Certified 6˝ Stainless Steel Legs with adjustable | ||
■ | flanged feet for a one inch level adjustment. | |
Gas Pressure Regulator and Control Valve. | ||
■ | Standard Voltage for Control: 115 volts, 60 Hz, single phase. | |
■ | Table Top includes 2˝ deep Drain Trough with 3⁄4˝ Drain and | |
| Grate | |
■ 6 gallon Tilting Kettle made of type 304 Stainless Steel, 2⁄3 jacketed | ||
| Kettle includes: | |
| ■ | Trunnion mounted Steam Control Valve |
| ■ | 50 psi Kettle Steam Jacket Rating |
| ■ | Lift Off Cover |
| ■ | Double Pantry Faucet with Swing Spout |
Options & Accessories
❐ Right Hand Door Hinging, Controls and Kettles on the Left DHR)(
MODELS: 42-CKGM-200 42-CKGM-300
|
|
| lG |
|
|
|
|
| |
|
|
| e | u |
|
|
|
| |
|
|
| k |
| a |
|
|
| |
|
|
|
|
| r |
|
|
| |
|
|
| c |
|
| d |
| ||
|
| N | i |
|
|
| |||
|
|
|
|
|
| ||||
|
|
|
|
| ™ | ||||
|
| 1 |
|
|
|
|
|
| y |
|
|
|
|
|
|
|
| t | |
|
| 0 |
|
|
|
|
|
| n |
|
| % |
|
|
|
|
| a | |
|
| 0 |
|
|
|
| r | ||
|
|
| 5 |
| rW | a | r |
| |
Shown with optional |
|
|
|
| |||||
| Y |
|
|
|
| ||||
| ear Boile |
|
|
|
| ||||
Electronic Timer |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| Short Form Specifications |
|
|
|
|
|
|
|
|
| Shall be Two Compartments, CLEVELAND Convection Steamer, plus one 6 | ||||||||
| gallon Direct Steam, tilting, kettle, Model | , | |||||||
| Generator, NickelGuard, _____ M BTU. Solid State Controls operate timing, | ||||||||
| water level and safety functions. Steam Generator with Automatic Water Fill | ||||||||
| on | ||||||||
| Electronic S park I gnition. Fo r each cooking compartment: | 60 minute | |||||||
| Mechanical Timer, Manual Operation Mode and Cold Water Condenser. Type | ||||||||
| 304 Stainless Steel cooking compartment. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
❐ Electronic Timer with Compensating Load Feature (ETC) |
|
|
|
| |||||
❐ | ON/OFF Steam Switch only for compartment controls (MC) |
|
|
| |||||
❐ | Compartment Door Steam Shut Off Switch (SCS) |
|
|
|
|
|
|
| |
❐ | Cafeteria pans in depths of 1˝, 21⁄2˝, 4˝ and 6˝ |
|
|
|
|
|
|
|
|
❐ | Power Take Off Kit (GPTO), Kettle Interconnecting Kit (IMK) |
|
|
| |||||
❐ | Correctional Packages |
|
|
|
|
|
|
|
|
❐ | Stainless Steel Base Frame (FSS) |
|
|
|
|
|
|
|
|
❐ | Stainless Steel Insulated Flue Cover (SSF) |
|
|
|
|
|
|
|
|
❐ | Quick Disconnect for gas line (QDC) |
|
|
|
|
|
|
|
|
❐ | Type 316 Stainless Steel Liner for high acid products |
|
| ||||||
❐ | Secondary Low Water |
|
|
|
|
| |||
| (Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. | ||||||||
| NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC) | ||||||||
❐ Boiler Descaling Pump Kit (107142) |
|
|
|
|
|
|
|
| |
❐ | Water Filters |
|
|
|
|
|
|
|
|
❐ | Rear Gas Connection (RGT) |
|
|
|
|
|
|
|
|
❐ | Compartment Door Steam Shut Off Switch |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1333 East 179 St., | Tel: | Web Site: www.ClevelandRange.com |
Cleveland, Ohio, U.S.A. 44110 | Fax: | Email: Steam@ClevelandRange.com |