Cleveland
COMBI OVEN-STEAMER
Stacking Kits for Gas Table Type Models
(OGB 6.10 on OGB 6.10 or OGS 6.10 on OGS 6.10)
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
| Model # | Description |
| for mounting two 6.10 models | |
byCleveland |
| for mounting two 6.10 models (with casters) |
LEFT SIDE VIEW
36.70" |
39.21" |
UNIT A |
G | D | W1 W2 | RC | CS |
|
| UNIT B |
|
|
|
|
|
|
|
|
HOOD REQUIREMENT) |
| |
67.85" | ||
78.00”(MIN. |
|
38.08"
2.52"
28.43
5.00"
28.43
1.58" | 1.82" |
| |
| UNIT A |
4.38"
6.00"
G D W1 W2 RC CS
NOTE: Overall height of unit does not change for units with casters.
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"
•Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.
•Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).
•Installation must comply with all local fire and health codes.
| Electrical Requirements: | 120 volt, 60 Hz, single phase, UNIT A - 11.7 amps | |
| Do not connect to a G.F.I. outlet. |
| UNIT B - 11.7 amps |
|
|
|
|
G | Gas Connection: | 3/4" NPT |
|
| Gas Type: | Natural Gas (Propane optional) | |
| Gas Flow Pressure: | Natural Gas - Min. 5.5" WC / Max. 14" WC | |
|
| Propane Gas - Min. 11" WC / Max. 14" WC | |
|
|
|
|
| BOILER MODELS | UNIT A - | UNIT B - |
| Total Connected Load: | 45.400 BTU | 45.400 BTU |
| Steam Generator: | 45.400 BTU | 45.400 BTU |
| Hot Air: | 45.400 BTU | 45.400 BTU |
|
|
|
|
| BOILERLESS MODELS | UNIT A - | UNIT B - |
| Total Connected Load: | 45.400 BTU | 45.400 BTU |
| Hot Air: | 45.400 BTU | 45.400 BTU |
|
|
|
|
| Water Connections: | Cold Water (drinking water quality) |
| Flow Pressure: | 30 - 60 PSI |
| Water Inlets: | 3/4" |
| W1 | Treated Water for Steam Generator |
| W2 | Untreated Water for Condenser |
|
|
|
D Drain Connection: | 2" Tube | |
|
|
|
| Venting: | Exhaust Hood required |
|
|
|
CS *Connection for Cleaning Solution
RC *Connection for Rinse Cycle
*Available as an option
Note: For additional connection details, see spec sheet for each individual combi model to be stacked.
SECT. IIB PAGE 5A 0707