Cleveland Range CSTK-610CA OEB 6.10 on OEB 10.10 or OES 6.10 on OES, byCleveland, Model #

Models: CSTK-610 CSTK-610CA

1 8
Download 8 pages 30.38 Kb
Page 6
Image 6
(OEB 6.10 on OEB 10.10 or OES 6.10 on OES 10.10)

Manual backgroundCleveland

COMBI OVEN-STEAMER

Stacking Kits for Electric Table Type Models

(OEB 6.10 on OEB 10.10 or OES 6.10 on OES 10.10)

Project ________________________________

Item __________________________________

Quantity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

 

Model #

Description

 

CSTK-1010

for mounting one 6.10 model on top of one 10.10 model

byCleveland

CSTK-1010CA

for mounting one 6.10 model on top of one 10.10 model (with casters)

LEFT SIDE VIEW

37.83"

UNIT A

D

W1 W2

RC

CS

 

UNIT B

 

 

48.54"

4.38"

 

 

 

 

 

 

REQUIREMENT)

 

78.41"

 

80.00”(MIN. HOOD

 

 

 

 

2.52"

28.43

5.00"

38.98"

6.00"

36.70"

 

1.58"

1.82"

 

UNIT A

 

UNIT B

D W1 W2

RC CS

NOTE: Overall height of unit does not change for units with casters.

UTILITIES (Utility connection shown below are listed per unit)

Required Clearances: Rear - 2", Left Side - 4", Right Side - 2 1/2"

Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to the unit.

Allow for sufficient clearance on left side for service access (contact the factory service department for recommendations).

Installation must comply with all local fire and health codes.

Electrical Requirements: Do not connect to a G.F.I. outlet.

BOILER

UNIT A - OEB-6.10

 

 

UNIT B - OEB-10.10

 

 

MODELS

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

 

 

Total Connected Load:

9.9 KW

12.8 KW

11 KW

13.1 KW

16.4 KW

21.6 KW

18.5 KW

22 KW

Hot Air:

8.6 KW

11.4 KW

9.1 KW

10.2 KW

14.7 KW

19.6 KW

16.5 KW

19.6 KW

Steam Generator:

7.7 KW

10.2 KW

8.6 KW

10.2 KW

12.8 KW

17.1 KW

14.3 KW

17.1 KW

Amps per Phase:

27.3

30.8

15.2

16.3

45.5

51.8

24.2

26.4

 

 

 

 

 

 

 

 

BOILERLESS

UNIT A - OES-6.10

 

 

UNIT B - OES-10.10

 

 

MODELS

208/3/60

240/3/60

440/3/60

480/3/60

208/3/60

240/3/60

440/3/60

480/3/60

 

 

 

Total Connected Load:

9.9 KW

12.8 KW

11 KW

13.1 KW

6.4 KW

21.6 KW

18.5 KW

22 KW

Hot Air:

8.6 KW

11.4 KW

9.1 KW

10.2 KW

14.7 KW

19.6 KW

16.5 KW

19.6 KW

Amps per Phase:

27.3

30.8

15.2

16.3

45.5

51.8

24.2

26.4

 

 

 

 

 

 

 

 

 

 

 

 

Water Connections:

Cold Water (drinking water quality)

 

Flow Pressure:

30 - 60 PSI

 

 

 

Water Inlets:

3/4" GHT-F (Female Garden Hose

 

 

Connection)

 

 

 

W1

Treated Water for Steam Generator

 

W2

Untreated Water for Condenser

 

 

 

 

 

D

Drain Connection:

2" Tube

 

 

 

 

 

 

 

Venting:

Exhaust Hood required

 

 

 

 

CS

*Connection for Cleaning Solution

 

 

 

 

 

 

 

 

RC

*Connection for Rinse Cycle

 

 

 

 

 

 

 

 

 

 

 

*Available as an option

 

 

 

 

 

Note: For additional connection details,

 

 

 

 

 

 

 

 

see spec sheet for each individual

 

SECT. IIB PAGE 5F

 

combi model to be stacked.

 

 

0707

1333 East 179 St.,

Tel: 1-216-481-4900

Web Site: www.ClevelandRange.com

Cleveland, Ohio, U.S.A. 44110

Fax: 1-216-481-3782

Email: Steam@ClevelandRange.com

Page 6
Image 6
Cleveland Range CSTK-610CA manual OEB 6.10 on OEB 10.10 or OES 6.10 on OES, byCleveland, Model #, Description, Venting