A1

 

 

 

 

 

 

 

MANUAL TILT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A2

 

 

 

 

 

EXTENDED FOR

 

 

 

 

POWER TILT

 

 

 

 

 

POWER TILT OPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

C

S

 

 

 

 

7/16" (11 mm) Ø

4 7/8"

 

 

3 HOLES ON

124 Ø mm

 

 

3 1/8" (80 mm) Ø

 

 

 

 

B.C.D.

 

 

 

D

 

120º

 

 

 

TYP

 

NOTE: TD3, 3" tangent draw off will

1 5/8" (42 mm) Ø

 

 

 

 

 

raise height of kettle by 5-5/8" (143mm).

 

 

 

Available on 60 gallon models only.

1" (25 mm)

 

9/16"

 

 

 

 

 

MAX. ADJUSTMENT

14 mm

 

 

FLANGED FOOT DETAIL

CAPACITIES: (in 8 oz. servings, other sizes may be calculated.)

25 Gallon / 100 liters . . . 400 servings 40 Gallon / 150 liters . . . 640 servings 60 Gallon / 225 liters . . . 960 servings

 

L

K

M

J

2 3/4

 

N

 

 

 

 

FLOOR DRAIN

 

O

(18" WIDE)

 

 

E

HANDWHEEL REPLACED BY

SWITCH FOR POWER

TILT OPTION

T (I.D.)

F

4" (102 mm)

RECOMMENDED

 

 

RECOMMENDED

FLOOR SLOPE

H

C

 

1" (26 mm) per 4' (1220 mm)

 

 

 

 

PIPE DRAIN RECOMMENDED

 

 

 

min. valve size plus 1" (26 mm)

 

 

 

 

G

H

 

 

 

UNIT SHOWN WITH OPTIONAL 2" TANGENT DRAW-OFF VALVE,

SPRING ASSIST COVER, HOT AND COLD WATER FAUCED AND STEAM CONTROL KIT.

DIMENSIONS

GALS./

 

A1

A2

B

C

D

E

F

G

H

J

K

L

M

N

0

S

T I.D.

LITERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

IN

37 5/8

35 1/2

33 3/8

28 5/8

15 3/8

61 7/8

36 5/8

14

18 1/2

15 1/2

14 1/2

14 1/4

21 5/8

49 1/4

3 7/8

29 5/8

21

100

mm

957

902

848

728

391

1572

931

356

470

394

369

362

550

1251

99

753

534

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

IN

41 5/8

39 1/2

34 3/4

30

17 7/8

65 7/8

36 7/8

12 1/4

19

16 1/2

17

16 3/4

23 3/8

51 1/8

6 3/8

32 3/8

26

150

mm

1058

1004

883

762

455

1674

937

312

483

420

432

426

594

1299

162

823

661

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

IN

45 1/8

43

38

33 3/8

19 5/8

74 1/8

40 7/8

12 3/4

20 1/4

18 1/2

18 3/4

18 1/2

26 5/8

56 3/8

8 1/8

36 1/4

29 1/2

225

mm

1147

1093

966

848

499

1883

1039

324

515

470

477

470

677

1432

207

921

750

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Installation of backflow preventers, vacuum breakers and other specific coder requirements is the responsibility of the owner and installer.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.

(NOT TO SCALE) SECT. X PAGE 10 0707

Litho in U.S.A.

Page 2
Image 2
Cleveland Range KDL-25-T, KDL-40-T, KDL-60-T Capacities in 8 oz. servings, other sizes may be calculated, 100, 150, 225