Cleveland Range OES-3.10 Electrical Connections, Cold Water Connection, Drain Connection

Models: OES-3.10

1 2
Download 2 pages 30.91 Kb
Page 2
Image 2
ELECTRICAL CONNECTIONS

6.46”

5.63”

5.69”

11.89”

35.06”

31.23”

23.04”

2.44”

2.52”

 

20.28”

29.27”

 

27.74”

 

4.06”

 

16.93”

ELECTRICAL CONNECTIONS

The 3 phase 208-240 volt units will be supplied with a 10 AWG,SOOW, 4 conductor 6 foot long cord. The customer will have to provide the NEMA plug (NEMA # 15-30P or L15-30P). Unit current rating 24 amps.

The 1 phase 208-220 volt units will be supplied with a 10 AWG, SOOW, 3 conductor 6 foot long cord. The customer will have to provide the NEMA plug (NEMA # 6-30P or L6-30P). Unit current rating 24 amps.

The 1 phase 240 volt units will be supplied with a 10 AWG, SOOW, 3 conductor 6 foot long cord. The customer will have to provide the NEMA plug (NEMA # 6-50P or L6-50P). Unit current rating 25.5 amps.

These units cannot be hard wired to the circuit box. They must have a NEMA plug to be connected to a mating NEMA receptacle (customer supplied) to comply with the U.L. and NEC electrical standards.

COLD WATER CONNECTION

One 3/4" GHT (Garden Thread Hose) connection. Use NSF approved hose.

35 PSI minimum, 60 PSI maximum.

DRAIN CONNECTION

1 1/2" tube.

Do not connect other units to this drain.

Drain line must be vented.

SERVICE CLEARANCES

3" left, 3" right, 3" rear, allow 20" on top for service.

APPROVALS

UL and UL Sanitation.

SHIPPING WEIGHT

NOTES:190 lbs.

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers.