The Floor Drain must be located outside the con- fines of the equipment.
1 1/2” IPS common drain.
Do not connect other units to this drain.
Do not use PVC pipe for drain.
Cleveland Range reserves right of design improvement or modification, as warranted.
•Each compartment has capacity for:
Eight, | 12˝ x 20˝ x 21⁄2˝ | Cafeteria Pans or |
Six, | 12˝ x 20˝ x 4˝ | Cafeteria Pans or |
Four, | 12˝ x 20˝ x 6˝ | Cafeteria Pans or |
Four, | 18˝ x 26˝ | Bun Pans |
•Many regional, state and local codes exist and it is
the responsibility of the owner and installer to com- ply with those codes.
•Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, ULC, NSF, and CSA.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY | less than 20 parts per million |
SILICA | less than 13 parts per million |
pH FACTOR | greater than 7.5 |
CHLORINE | less than 30 parts per million |
Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator.
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoining wall or equipment is over 30” high for service access)
Contact factory for variances to clearances.
(NOT TO SCALE) SECT. VI PAGE 8 0707