Image 1
Cleveland

PRESSURE STEAMERSCleveland

PRESSURE STEAMERS

Project ________________________________

Item __________________________________

Quantity _______________________________

FCSI Section ____________________________

Approval _______________________________

Date __________________________________

PRESSURE STEAMERS

2 OR 3 COMPARTMENTS STEAM COIL GENERATOR 36” WIDE CABINET BASE

MODELS: χ PSM-2

χ PSM-3
2 Compartments3 Compartments
Cleveland Standard Features

5 psi Operating Pressure in cooking compartments

Mechanical interlock prevents unlatching door while compartment is pressurized

Timers, one per compartment, are mechanical style with audible signal

Thermostatic Trap vents cooking compartment automatically

Steam Inlet Valves and Exhaust Valves interlocked for synchronous action

8 psi Compartment Safety Valve

Capacity per compartment for eight, 12” x 20” x 2 1/2” deep Cafeteria Pans, or four, 18” x 26” Bun Pans

Heavy Duty, free floating, cast aluminum compartment doors

Compartment Door Hinges have adjustable hinge pins and self-lubricating bushings

Door Gasket replaceable without tools

Pressure Gauge for compartment Operating Pressure

Compartment Slide Racks are removable without tools, for easy cleaning

Type 430 Stainless Steel: external enclosure, Table Top and eight gauge plate cooking compartments

Modular Cabinet Base with Hinged Doors

High efficiency Electric Steam Generator with Automatic Water Fill on start-up

Automatic Water Level Control System with Low Water Power Cut-off Circuit

Steam Generator equipped with High-limit Pressure Safety Switch and Safety Valve

Automatic Steam Generator (boiler) Blowdown allows intermittent control, complete with additional Manual Drain Valve

Single cold water Connection (no hot water required)

6” Stainless Steel Legs with level adjustment and flanged feet Secondary Low Water Cut-Off, factory installed (CALS)

(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)

Standard Voltage for Controls, 115 volts, 60 Hz, single phase

All major components are serviceable from the front of unit

Short Form Specifications

Shall be _____ Compartments, CLEVELAND, Pressure Steamer,

Model PSM- _____ , Steam Coil Steam Generator, _____ volts, single

phase. Each Cooking Compartment equipped with: 60 Minute Timer;

Pressure Safety Valve: Heavy-duty, free floating Door with Safety Interlock; and synchronous operating Steam Inlet and Exhaust/Drain Valves. Solid State Controls operate Water Level and Steam Generator (boiler) Safety Functions. Automatic Steam Generator (boiler) Blowdown with additional Manual Drain Valve.

Pressure Reducing Valve for 50 to 120 psi steam pressure (PRV)

Moisture Separator for steam supply (MS)

Stainless Steel base Frame (FSS)

Special Compartment Slide Racks

12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep

Intermediate Pull-Out Shelf (POS)

Spray Head with flexible Hose (SH)

Water Filters

Rear Gas Connection (RGT)

Options & Accessories

Automatic Steam Inlet and Exhaust Operation (AT-2):

includes 60 minute Automatic Timers and Manual Bypass

 