![Cleveland](/images/new-backgrounds/68940/689401x1.webp)
™
Cleveland
PRESSURE STEAMERS
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
PRESSURE STEAMERS
2 OR 3 COMPARTMENTS STEAM COIL GENERATOR 36” WIDE CABINET BASEMODELS: χ | χ |
2 Compartments | 3 Compartments |
■ 5 psi Operating Pressure in cooking compartments
■ Mechanical interlock prevents unlatching door while compartment is pressurized
■ Timers, one per compartment, are mechanical style with audible signal
■ Thermostatic Trap vents cooking compartment automatically
■ Steam Inlet Valves and Exhaust Valves interlocked for synchronous action
■ 8 psi Compartment Safety Valve
■ Capacity per compartment for eight, 12” x 20” x 2 1/2” deep Cafeteria Pans, or four, 18” x 26” Bun Pans
■ Heavy Duty, free floating, cast aluminum compartment doors
■ Compartment Door Hinges have adjustable hinge pins and
■ Door Gasket replaceable without tools
■ Pressure Gauge for compartment Operating Pressure
■ Compartment Slide Racks are removable without tools, for easy cleaning
■ Type 430 Stainless Steel: external enclosure, Table Top and eight gauge plate cooking compartments
■ Modular Cabinet Base with Hinged Doors
■ High efficiency Electric Steam Generator with Automatic Water Fill on
■ Automatic Water Level Control System with Low Water Power
■ Steam Generator equipped with
■ Automatic Steam Generator (boiler) Blowdown allows intermittent control, complete with additional Manual Drain Valve
■ Single cold water Connection (no hot water required)
■ 6” Stainless Steel Legs with level adjustment and flanged feet ❐ Secondary Low Water
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
■Standard Voltage for Controls, 115 volts, 60 Hz, single phase
■All major components are serviceable from the front of unit
Shall be _____ Compartments, CLEVELAND, Pressure Steamer,
Model PSM- _____ , Steam Coil Steam Generator, _____ volts, single
phase. Each Cooking Compartment equipped with: 60 Minute Timer;
Pressure Safety Valve:
❐Pressure Reducing Valve for 50 to 120 psi steam pressure (PRV)
❐Moisture Separator for steam supply (MS)
❐Stainless Steel base Frame (FSS)
❐Special Compartment Slide Racks
❐12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep
❐Intermediate
❐Spray Head with flexible Hose (SH)
❐Water Filters
❐Rear Gas Connection (RGT)
❐Automatic Steam Inlet and Exhaust Operation
includes 60 minute Automatic Timers and Manual Bypass |
| SECT. | VI | PAGE 5 | |
|
| 0707 | |||
|
|
|
|
|
|
1333 East 179 St., | Tel: |
|
|
| |
Web Site: www.ClevelandRange.com |
|
|
| ||
Cleveland, Ohio, U.S.A. 44110 | Fax: | Email: Steam@ClevelandRange.com |
|
|
|
|
|
|
|
|
|