TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

This section contains information intended for use by Authorized Service Personnel only.

PROBLEM

A/ Kettle heats too slowly or does not come to a boil.

Probable Cause

1.Inadequate steam flow.

2.Steam trap not operating properly.

3.Food batches are not always the same.

PROBLEM

B/ The trunnion housing leaks steam.

Probable Cause

1.Trunnion "O" rings are worn.

Remedy

Check for correct steam using chart below.

If kettle is connected to a steamer and powered by a generator the units should be operated sequentially (kettle boiling first, then start steamer).

The trap should open periodically to dump condensate, then close.

If it does not open or close it should be cleaned or replaced.

When checking make certain that the original state (ie. fresh or frozen) and quantity of food product is the same.

Remedy

Replace "O" rings (see STEAM CONTROL ASSEMBLY drawing).

STEAM FLOW RATING

OF STEAM GENERATORS

Gas Input

Steam Output

Boiler

BTU/Hour

Lbs./Hour

H.P.

 

100,000

60

1.7

 

160,000

95

2.8

 

200,000

125

3.6

 

250,000

150

4.4

 

300,000

180

5.2

 

 

Electric

 

 

 

 

KW Input

 

 

 

 

 

 

 

 

18

60

1.7

 

24

70

2.0

 

27

90

2.6

 

36

120

3.5

 

48

150

4.4

 

 

 

 

 

 

STEAM FLOW RATING

REQUIREMENTS FOR KETTLES

Capacity

Fast

Medium

Stock

Gal./Lit.

Cooking

Cooking

Kettle

 

 

 

 

5/17

11

9

6

10/42

22

18

11

25/95

55

44

28

40/151

88

70

44

60/227

132

105

66

Electric: Above shows lbs. per hour with 10-15 psig steam at the kettle. The use of higher steam pressures (20-25 psig) will reduce heat-up time 5-20%.