Image 14
Low heat during operation

Maintenance

PROBLEM

LIKELY CAUSE

SOLUTION

Low heat during operation

Low incoming water temperature

Turn up supply water heater

 

(below 140° F)

 

 

Insulate supply water pipe

 

Thermostat out of adjustment

Adjust thermostat

 

(Optional) sustainer heater not

Install (optional) sustainer

 

installed

heater

 

 

P/N: 04109.10

 

Defective sustainer heater

Replace heater

 

 

P/N: 04109.10

Low spray arm water flow

Limed up spray arm nozzles

De-lime spray arm nozzles

 

 

 

With power on, activating

Defective fill/start switch (cycle

Replace fill/start switch

start switch does not begin

light will not light either)

P/N: 03470.01

cycle

 

 

Defective timer assembly

Replace timer assembly*

 

 

(Cam 1)

P/N: 00408.80

Start switch requires more

Defective (Instant Start) ice cube

Replace ice cube relay

than 1-second activation to

relay

P/N: 00631.00

run cycle

 

 

Activating fill switch does

Defective fill/start switch

Replace fill/start switch

not fill machine

 

P/N: 03470.01

 

Defective water solenoid valve

Replace water solenoid valve

 

 

P/N: 03603.10

Fill water won’t shut off

Defective water solenoid valve

Replace water solenoid valve

 

 

P/N: 03603.10

 

Defective fill/start switch

Replace fill/start switch

 

 

P/N: 03470.01

 

Defective timer assembly

Replace timer assembly*

 

(Cam 4)

P/N: 00408.80

Activating drain switch

Drain hose is kinked

Un-kink drain hose

does not drain machine

 

 

Defective drain switch

Replace drain switch

 

 

 

P/N: 03406.64

 

Defective drain valve motor

Replace drain valve motor

 

(Pump will still run)

P/N: 04103.21

 

 

 

Detergent pump does not

Defective detergent pump motor

Replace pump motor

run

 

P/N: 00416.00

 

Defective timer assembly

Replace timer assembly*

 

(Cam 2)

P/N: 00408.80

Sani pump does not run

Defective sani pump motor

Replace pump motor

 

 

P/N: 00416.00

 

Defective timer assembly

Replace timer assembly*

 

(Cam 5)

P/N: 00408.80

 

 

 

*The timer assembly motor (P/N: 00501.00) or micro switches (P/N: 00411.00) can be replaced independently if that is the only component that has failed.

MODEL L-1X & L-1X16 PARTS MANUAL Rev. 1.14