Cobra Electronics CPI 2575 warranty Operating Limits Power Output, Input Voltage

Models: CPI 2575

1 15
Download 15 pages 63.38 Kb
Page 12
Image 12

10276_CPI2575_PH1 8/20/07 2:33 PM Page 18

Operating Indicators

Operating Limits

Operation

 

High Temperature

Over Temperature Protection –

If the internal inverter temperature rises above the alarm threshold,

Operation

Operating Limits

Power Output

the meter will flash as shown, an alarm will sound to indicate Over Temperature Protect, and the unit will continue to operate. If the internal temperature rises to 40ºC (104ºF), the inverter will shut down to protect itself, the meter will flash as shown and the alarm will continue to sound.

NOTE Internal inverter temperature can rise due to being operated in a high heat environment or due to the fan or vents being blocked during operation (even in relatively cool outside air).

To restore normal operation, turn the unit Off and allow it to cool. The inverter will automatically return to normal operation after it has cooled.

The inverter can deliver 2500 watts for about 60 minutes. The inverter must cool for 15 minutes before it can resume operation at 2500 watts. Note: The wattage rating applies to resistive loads.

The inverter will operate most AC loads within its power rating. Some induction motors used in freezers, pumps, and other motor-operated equipment require very high surge currents to start. The inverter may not be able to start some of these motors even though their rated current draw is within the inverter’s limits. The inverter will normally start single phase induction motors rated at one-half HP or less.

Input Voltage

The inverter will operate from input voltage ranging from 10 volts to 15 volts. Optimum performance will occur when the voltage is between 12 volts and 14 volts. If the voltage drops below 10.5V+/- 0.3V, an audible low battery warning will sound. The inverter will shut down if the input voltage drops below 9.5V+/- 0.3V. This protects the battery from being over-discharged. It will restart when the input voltage exceeds 12V+/- 0.3V.

The inverter will also shut down if the input voltage exceeds 15.5V+/- 0.5V. This protects the inverter against excessive input voltage. Although the inverter has protection against over-voltage, it may still be damaged if the input voltage were to exceed 16 volts.

 

 

 

 