Troubleshooting
Problem | Possible Cause | Solution |
|
|
|
Burner won’t light | Cylinder valve is closed | Open valve |
|
|
|
| Gas pressure is low | Turn Cylinder valve OFF and replace cylinder |
|
|
|
| Air in gas line | Burner may take 20 seconds to light after a propane bottle |
|
| has been connected |
|
|
|
| Low gas pressure with Cylinder Valve | Cylinder is empty. Replace cylinder |
| fully open |
|
|
|
|
| Igniter fails | Replace AAA Battery |
|
|
|
| Improper purging of new 20 lb. cylinder | Attach cylinder to other appliance (Grill) to purge |
|
| air from line. |
|
|
|
Burner won’t stay lit | Gas pressure is low | Turn Cylinder valve OFF and replace cylinder |
|
|
|
| Outdoor temperature is less than 40° F | Use a full cylinder |
| and tank is less than 1/4 full |
|
| Supply hose is bent or kinked | Straighten hose |
|
|
|
Adhesive Panels | Panels exposed to direct sunlight | Move out of direct sunlight. If desired, replace. |
dripping |
|
|
|
|
|
Service
•Repair to gas passages and associated components should be done only by a qualified service person.
•Owner repair & service should be limited and performed only to the following:
-Octenol Lure replacement
-Adhesive Trap replacement
-Cylinder replacement
-Listed parts replacement (See Replacement Parts List)
-Routine Cleaning
Mosquito DeletoTM Refills
Mosquito DeletoTM | Mosquito DeletoTM Inhibitor |
Octenol Lure Refill | Model # |
| |
Model # |
|
Mosquito DeletoTM
Trap Cartridge Refill
Model #
Mosquito DeletoTM |
|
System Refill | Mosquito DeletoTM |
Model # | Inhibitor Refill |
| Model # |
10
All Mosquito DeletoTM refills are available at www.coleman.com or