5 To Pump (Coleman® Fuel Bottle)
■Make sure FUEL VALVE is fully “OFF” (Fig 12).
■Connect hose to threaded fitting on fuel bottle, making sure the bottle is lying on its side with the fuel valve up. Hand tighten the connection (Fig. 13).
■Place thumb over hole in PUMP KNOB and pump approximately 40 full strokes (Fig 14). Adequate air pressure is important, do not over pump.
FIG. 12 | FIG. 13 | FIG. 14 |
6 Leak Check (Coleman® Fuel Bottle)
WARNING
•Perform leak test outdoors.
•Extinguish all open flames.
•NEVER leak test when smoking.
•Do not use the outdoor stove until connection has been leak tested and does not leak.
WARNING
•BURN HAZARD
•Never leave stove unattended when hot or in use.
•Keep out of reach of children.
■ Make sure FUEL VALVE is fully “OFF” | . |
■CHECK FOR LEAKS in one or more ways: Look for a fuel mist or a wet appearance of fuel on surfaces. Listen for hiss of escaping gas.
Smell for fuel odor. Never use a flame. Do not use if leaking.
CHECK FOR LEAKS
Liquid Fuel Canister
FIG. 15