Recommended Filter Sizes
CFM | Cabinet | Side | Bottom | |
Size | (in) | (in) | ||
| ||||
|
|
|
| |
1200 | A | 16 x 25 | 14 x 25 | |
1200 | B | 16 x 25 | 16 x 25 | |
1600 | C | 16 x 25 | 20 x 25 | |
2000 | C | (2) 16 x 25 | 20 x 25 |
NOTES:
1.Air velocity through throwaway type filters may not exceed 300 feet per minute (91.4 m/min). All velocities over this require the use of high velocity fil- ters.
2.Do not exceed 1800 CFM using a single side return and a 16x25 filter. For CFM greater than 1800, you may use two side returns or one side and the bottom or one return with a transition to allow use of a 20x25 filter.
Unit Clearances to Combustibles (All dimensions in inches, and all surfaces identified with the unit in an upflow configuration)
Application | Top | Front | Rear | Left | Right | Flue | Floor/ | Closet | Alcove | Attic | Line | |
Side | Side | Bottom | Contact | |||||||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |
Upflow | 1 | 6 | 0 | 0 | 3 | 6 | Combustible | Yes | Yes | Yes | No | |
|
|
|
|
|
|
|
|
|
|
|
| |
Upflow | 1 | 3 | 0 | 0 | 0 | 1 | Combustible | Yes | Yes | Yes | No | |
|
|
|
|
|
|
|
|
|
|
|
| |
Downflow | 1 | 6 | 0 | 0 | 3 | 6 | 11 | Yes | Yes | Yes | No | |
Downflow | 1 | 3 | 0 | 0 | 0 | 1 | 11 | Yes | Yes | Yes | No | |
Horizontal | 1 | 6 | 0 | 0 | 3 | 6 | Combustible | No | Yes | Yes | Yes2 | |
Horizontal | 1 | 3 | 0 | 0 | 0 | 1 | Combustible | No | Yes | Yes | Yes2 |
1.Special floor base or air conditioning coil required for use on combustible floor.
2.Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and build- ing joists, studs or framing.
ACCESSORIES
PROPANE (LP) CONVERSION KIT -
1NP0347 - All Models
This accessory conversion kit may be used to convert natural gas units for propane (LP) operation.
SIDE RETURN FILTER RACKS - 1SR0200 - All Models 1SR0302 - All Models
BOTTOM RETURN FILTER RACKS -
1BR0514 or 1BR0614 - For
1BR05xx series are galvanized steel filter racks. 1BR06xx are
COMBUSTIBLE FLOOR BASE KIT -
For installation of these furnaces in downflow applications directly onto combustible flooring material. These kits are required to prevent potential overheating situations. These kits are also required in any applications where the furnace in installed in a downflow configuration without an evaporator coil, where the combustible floor base kit provides access for combustible airflow.
1CB0514 - For
EAC TRANSITION KITS -
For installation of EAC accessories with these furnaces to provide easy transition of return airflow through the EAC to get the proper sealing and reduced airflow leakage.
1TK1001 - For all models using side return 1TK1014 - For
MASONRY CHIMNEY KITS -
1CK0603
1CK0604
For installations where these furnaces are vented using existing or new lined masonry chimneys.
HIGH ALTITUDE PRESSURE SWITCHES -
For installation where the altitude is less than 5,000 feet it is not required that the pressure switch be changed. For alti- tudes above 5,000 feet, see kits below.
1PS3301
1PS3302
ROOM THERMOSTATS - A wide selection of compatible thermosets are available to provide optimum performance and features for any installation.
1H/1C, manual
1H/1C, auto/manual changeover, electronic programmable, deluxe
1H/1C, auto/manual changeover, electronic programmable.
*For the most current accessory information, refer to the price book or consult factory.