Removal and replacement procedures
Maintenance and Service Guide 4–25
14. If it is necessary to replace the webcam (select models only), lift the webcam 1 as far from the display
enclosure as the cable allows. The webcam is secured with double-sided tape and is available using spare part
number 531202-001.
15. Disconnect the display panel/webcam cable 2 from the webcam.
16. If it is necessary to replace the display hinges, remove the two Phillips PM2.5×5.0 screws 1 that secure each
hinge to the display panel.
17. Remove the display hinges 2. The Display Hinge Kit is available using spare part number 530993-001.