Compatible Systems OCTAL V.35 manual WAN Interface Configuration, Physical Communications Settings

Models: OCTAL V.35

1 18
Download 18 pages 46.56 Kb
Page 10
Image 10

Chapter 2 - Quickstart Instructions

6

DECnet Protocol

Required for DECnet

The router’s shipping configuration does not have DECnet turned on. In order to be used, DECnet must be turned on both globally and for a particular port.

Set DECnet on (globally, and for this port)

Set DECnet area

Set DECnet node

CV: Use the DECnet Routing Dialog Box (under Global/DECnet Routing) and the DECnet: Ethernet Dialog Box.

TB: Use configure and set the Mode keyword in the DECnet Ethernet 0 (and/or any other port numbers you wish to configure) section. Use configure and set the Enabled, Area, and Node keywords in the DECnet Global section.

ϖNote: Setting DECnet on for any port with the command line also sets DECnet on globally. In CompatiView you must set a global parameter and a port-specific parameter.

Suggested for DECnet

Setting the parameters above should be adequate for most installations.

WAN Interface Configuration

The default setting for all WAN interfaces on your Octal V.35-Quad 10/100 RIOP is Off for all protocols and for the link configuration. In order to use a WAN interface, you must first set some physical parameters and then set up the link and protocol parameters.

Physical Communications Settings

You may need to set the baud rate or other physical communications parameters for the WAN interface. These parameters will depend on the line communications device you are using.

CV: Use the Physical Configuration: WAN Dialog Box.

TB: Use configure and the V.35 Interface WAN 0 (and/or any other port numbers you wish to configure) section.

PPP Configuration

This section covers the settings required for PPP (point-to-point) protocol operation of the V.35 WAN interfaces.

WAN Link Configuration

Required for Dedicated/Leased Line Operation

Dedicated line operation is the simplest to set up.

Set Dedicated connection

Set PPP connection

CV: Use the Link Configuration: WAN Dialog Box.

TB: Use configure and then set the Mode and ConnectMode keywords in the Link Config WAN 0 (and/or any other port numbers you wish to configure) section.

Suggested for Dedicated Line Operation

Dedicated line operation generally does not require additional parameters for operation.

Page 10
Image 10
Compatible Systems OCTAL V.35 manual WAN Interface Configuration, Physical Communications Settings, PPP Configuration

OCTAL V.35 specifications

Compatible Systems OCTAL V.35 is a sophisticated networking product designed to enhance communication among various devices within a digital network. This innovative solution incorporates advanced technologies that enable seamless data transfer, robustness, and versatility in diverse environments.

One of the hallmark features of the OCTAL V.35 is its octal architecture, which allows for multiple data connections simultaneously. This architecture is particularly advantageous for organizations that require high-bandwidth data transmission and need to connect numerous devices at once. The ability to manage several connections helps reduce latency and optimize network performance.

The OCTAL V.35 is equipped with V.35 interfaces, which are essential for high-speed circuit-switched data transmission. This makes it ideal for applications requiring reliable and fast data communication. Its compatibility with V.35 enables the device to support a variety of networking standards and protocols, making it an excellent choice for interconnecting legacy systems with modern technologies.

Another prominent characteristic of the OCTAL V.35 is its built-in redundancy features. To ensure uninterrupted service, the system is designed to automatically switch to backup connections in case of primary link failures. This ensures that critical data remains available and that operations continue seamlessly, providing peace of mind for organizations that rely on constant data flow.

The device also supports multiple operating modes, catering to various use cases. Whether it’s point-to-point, multipoint, or other networking configurations, the OCTAL V.35 can be easily tailored to meet the specific requirements of any application scenario.

Furthermore, compatibility with various network management protocols allows for easy monitoring and maintenance of the network, ensuring that performance levels are sustained and issues can be promptly addressed.

Security features are a priority within the OCTAL V.35. The system includes advanced encryption and access control protocols to safeguard sensitive data, making it suitable for use in environments where data security is paramount, such as financial institutions and healthcare organizations.

In conclusion, the Compatible Systems OCTAL V.35 combines cutting-edge technology with practical features to provide a versatile, reliable, and secure networking solution. Its ability to handle multiple connections, adapt to various configurations, and maintain security makes it an ideal choice for organizations seeking to optimize their digital communications.