Set or mount the vacuum pump in any convenient location.

Refer to the accompanying wiring diagram for connection of the main power supply and the conveying control circuit.You must provide a wall-mounted disconnect for three-phase electrical connection. Incoming voltage and current must match the electrical specifications on the pump data plate and serial tag. Check for proper rotation of the pump after power has been connected and before operation.

Install vacuum lines to loader stations and the dust collector. Connect the dust collector vacuum outlet to the pump inlet.

INSTALLING THE PUMP

Central

Vacuum Line

Positive

Displacement

Vacuum Pump

Material

Material

Inlet

Receivers

Receiving

Hoppers

Central Dust Collector

INSTALLATION AND OPERATION NOTE:

The pump inlet is equipped with a vacuum relief valve to prevent the vacuum from exceeding 12 in. Hg. Excessive vacuum will reduce the life of the pump and can destroy it.

For special applications requiring a higher vacuum level, consult Conair service. If the vacuum relief valve is adjusted by any person other than a factory service representative, the warranty is voided.

IMB036/0898

Positive Displacement Pump

4