BlueStorm Universal PCI
User Manual
Contact Information
CTIM-00015 Revision 0.10 June 4
Limited Lifetime Warranty
BlueStorm Installation Guide, Connect Tech Inc
Copyright Notice
Trademark Acknowledgment
Table of Contents
List of Figures
BlueStorm Installation Guide, Connect Tech Inc
Figure 10 BlueStorm External I/O Box Diagram
Table 2 HDB-44 Pinouts for BlueStorm/LP 4 Port Connector
Table 4 HDB-78 Pinouts for BlueStorm/SP 8 Port Connector
List of Tables
BlueStorm/SP Only
Customer Support Overview
Contact Information
sales@connecttech.com support@connecttech.com
BlueStorm Installation Guide, Connect Tech Inc
Features
Introduction
BlueStorm Installation Guide, Connect Tech Inc
BlueStorm Installation Overview
Hardware Configuration
RS-422/485 Electrical Interface Configuration
1. Hardware Configuration
Jumper Block Diagrams for BlueStorm
Multi-drop Slave Mode
Line Bias/Termination
BlueStorm Installation Guide, Connect Tech Inc
Figure 1 BlueStorm/LP Jumper Block Locations 2 Port Models
Figure 2 BlueStorm/LP Jumper Block Locations 4 Port Models
Figure 3 BlueStorm/LP Jumper Block Locations 8 Port Models
BlueStorm Installation Guide, Connect Tech Inc
Figure 4 BlueStorm/SP Jumper Block Locations 8 Port Models
Figure 5 BlueStorm/SP Opto Jumper Block Locations 4 Port Models
BlueStorm Installation Guide, Connect Tech Inc
Jumper blocks are not installed
Jumper Configuration for BlueStorm
Figure 6 BlueStorm/SP RJ-11 8 Port Model
BlueStorm Installation Guide, Connect Tech Inc
Figure 8 Jumper Configuration Example for BlueStorm/SP Opto Models
Figure 9 Jumper Configuration Examples for BlueStorm/SP RJ-11 Models
TxD Control
RxD Control
Table 1 DB-25 Male Pinouts for BlueStorm/LP 2 Port Connector
Connectors and Pinouts
BlueStorm Installation Guide, Connect Tech Inc
Signal
Table 2 HDB-44 Pinouts for BlueStorm/LP 4 Port Connector
BlueStorm Installation Guide, Connect Tech Inc
Signal
Signal
BlueStorm Installation Guide, Connect Tech Inc
Table 3 VHDCI-68 Female Pinouts for BlueStorm/LP 8 Port Connector
BlueStorm Installation Guide, Connect Tech Inc
Signal
Signal
Table 3 VHDCI-68 Female Pinouts for BlueStorm/LP Continued
BlueStorm Installation Guide, Connect Tech Inc
Signal
Signal
Table 4 HDB-78 Pinouts for BlueStorm/SP 8 Port Connector
…Continued on next page
BlueStorm Installation Guide, Connect Tech Inc
Signal
Table 4 HDB-78 Pinouts for BlueStorm/SP Continued
BlueStorm Installation Guide, Connect Tech Inc
Signal
Signal
Table 5 RJ-45 Pinouts for BlueStorm/SP Opto 4 Port Connector
BlueStorm Installation Guide, Connect Tech Inc
Signal
Signal
BlueStorm/SP Only
BlueStorm Installation Guide, Connect Tech Inc
Signal
Signal Direction
Table 8 RJ-11 Pinouts for BlueStorm/SP RJ-11 Ports 7 and 8 Only
CAG104K Technical Tip
BlueStorm Installation Guide, Connect Tech Inc
Pin No
Figure 10 BlueStorm External I/O Box Diagram
BlueStorm Installation Guide, Connect Tech Inc
Male DB-9 connectors Mounting bracket VHDCI-68 connector
External I/O Box part number IOBG08BLV1
Figure 12 RS-422/485 Wiring Diagrams BlueStorm/SP Opto Only
BlueStorm Installation Guide, Connect Tech Inc
RS-422/485 2 Wire Diagram
RS-422/485 4 Wire Diagram
Hardware Installation
Software/Driver Installation
Specifications
Storage temperature
Dimensions
Surge Suppression
Optical Isolation
UARTs
Certification
BlueStorm Installation Guide, Connect Tech Inc
Industry Industrie Canada Canada