BlueStorm Installation Guide, Connect Tech Inc.

Table 4: HDB-78 Pinouts for BlueStorm/SP (continued)

Pin

Port

RS-

Signal

RS-422/48

Signal

No.

No.

232

Direction

5

Direction

 

 

Signal

 

Signal

 

40

1

RTS

output

RTS A(-)

output

41

1

CTS

input

RTS B(+)

output

42

1

DSR

input

CTS A(-)

input

43

1

RI

input

CTS B(+)

input

44

1

SG

signal gnd.

SR

signal ref.

45

2

RTS

output

RTS A(-)

output

46

2

CTS

input

RTS B(+)

output

47

2

DSR

input

CTS A(-)

input

48

2

RI

input

CTS B(+)

input

49

3

RTS

output

RTS A(-)

output

50

3

CTS

input

RTS B(+)

output

51

3

DSR

input

CTS A(-)

input

52

3

RI

input

CTS B(+)

input

53

3

SG

signal gnd.

SR

signal ref.

54

4

RTS

output

RTS A(-)

output

55

4

CTS

input

RTS B(+)

output

56

4

DSR

input

CTS A(-)

input

57

4

RI

input

CTS B(+)

input

58

 

NC

no connect

NC

no connect

59

 

NC

no connect

NC

no connect

60

1

TxD

output

TxD A(-)

output

61

1

RxD

input

TxD B(+)

output

62

1

DTR

output

RxD A(-)

input

63

1

DCD

input

RxD B(+)

input

64

2

SG

signal gnd.

SR

signal ref.

65

2

TxD

output

TxD A(-)

output

66

2

RxD

input

TxD B(+)

output

67

2

DTR

output

RxD A(-)

input

68

2

DCD

input

RxD B(+)

input

69

3

TxD

output

TxD A(-)

output

70

3

RxD

input

TxD B(+)

output

71

3

DTR

output

RxD A(-)

input

72

3

DCD

input

RxD B(+)

input

73

4

SG

signal gnd.

SR

signal ref.

74

4

TxD

output

TxD A(-)

output

75

4

RxD

input

TxD B(+)

output

76

4

DTR

output

RxD A(-)

input

77

4

DCD

input

RxD B(+)

input

78

 

NC

no connect

NC

no connect

Cable CAG08FXDX and/or the IOBG08DB9V1 will send the signals to eight DB-9 male connectors. See Table 6 for the DB-9 pinouts. Cable CAG08DB25 will send the signals to eight DB-25 connectors. See Table 6 for the DB-25 pinouts.

18

Revision 0.08