BlueStorm Installation Guide, Connect Tech Inc.

Hardware Installation

Turn the power off to your computer and open it to expose the expansion slots (consult your system’s documentation for more information about this procedure).

Choose an available PCI expansion slot, remove the expansion slot cover and insert the BlueStorm adapter, pushing down gently until the board seats fully in the slot. Secure the BlueStorm card to the computer chassis.

Software/Driver Installation

BlueStorm provides support for QNX 4.X/6.X, Windows 2000/CE/XP/XPe/XP x64/Server 2003/Server 2003 x64,Vista, VxWorks, Ardence RTX and Linux. For installation guidelines and driver codes, please refer to the appropriate directories on the BlueStorm CD. For further information concerning software installation of BlueStorm products please visit Connect Tech’s Download Zone.

If you are interested in a device driver for an operating system not listed please contact the Connect Tech Sales Department.

Specifications

Operating Environment

BlueStorm/LP

 

Storage temperature:

-55°C to 125°C

Operating temperature: 0°C to 70°C

Humidity:

5 to 95% non-condensing

BlueStorm/SP, BlueStorm/SP Opto and BlueStorm/SP RJ-11

Storage temperature:

-55°C to 105°C

Operating temperature: 0°C to 70°C

Humidity:

5 to 95% non-condensing

PCI Bus Interface

BlueStorm/LP

3.3V or 5V PCI bus.

Please note that the BlueStorm/LP can ship with low and standard profile brackets.

BlueStorm/SP, BlueStorm/SP Opto and BlueStorm/SP RJ-11 3.3V or 5V PCI bus

Communications

Baud Rates

RS-232:50 bps – 921.6 Kbps

RS-422/485:50 bps – 1.8432 Mbps

Custom baud rates are also available; please contact our Sales Department for information.

Revision 0.08

23