AC

PHOTOMETRICS

 

 

 

 

 

 

AC-132

Candlepower

 

 

 

Electronic Ballast

 

 

 

 

 

(1) F32WT8/835 Lamp

Angle

Along II

45°

Across

 

2850 Lumens each

0

798

798

798

 

5

794

796

797

 

Spacing criterion:

 

10

783

789

795

(II) 1.2 x mounting

15

764

777

790

 

height, ( ) 1.4 x

20

738

760

783

 

25

705

739

771

 

mounting height

 

30

665

713

755

 

 

 

Efficiency 89.8%

35

620

682

735

 

Test Report:

40

570

647

708

 

45

516

606

675

 

AC-132.IES

 

50

458

560

634

 

LER = FL75 LPW

55

398

507

584

 

60

337

448

517

 

Yearly Cost of 1000

 

65

273

383

403

 

lumens, 3000 hrs at

70

207

296

276

 

.08 KWH = $5.01

75

142

192

171

 

 

80

81

102

89

 

 

85

31

31

22

 

 

90

0

0

0

Coefficients of Utilization

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

50%

 

 

30%

 

 

10%

 

0%

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

107

107

107

107

104

104

104

104

100

100

100

96

96

96

92

92

92

90

 

1

 

97

93

89

86

95

91

87

84

87

84

82

84

81

79

80

78

77

75

 

2

 

88

81

74

69

86

79

73

68

76

71

67

73

69

65

70

67

64

62

 

3

 

80

70

63

57

78

69

62

56

66

60

55

64

59

54

61

57

53

51

 

4

 

73

62

54

48

71

61

53

47

58

52

47

56

51

46

54

49

45

43

 

5

 

67

55

47

41

65

54

46

40

52

45

40

50

44

40

49

43

39

37

 

6

 

62

49

41

35

60

49

41

35

47

40

35

45

39

34

44

38

34

32

 

7

 

57

45

37

31

56

44

36

31

43

36

31

41

35

30

40

34

30

28

 

8

 

53

41

33

27

52

40

33

27

39

32

27

38

31

27

37

31

27

25

 

9

 

50

37

30

25

48

37

29

25

36

29

24

35

29

24

34

28

24

22

 

10

 

46

34

27

22

45

34

27

22

33

26

22

32

26

22

31

26

22

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Zone

Lumens

%Lamp

%Fixture

0-30

636

22.3

24.9

0-40

1062

37.3

41.5

0-60

1974

69.2

77.1

0-90

2559

89.8

100.0

0-180

2559

89.8

100.0

Luminance Data

 

Average

Average

Average

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

45

1963

2305

2568

55

1867

2378

2739

65

1738

2438

2565

75

1476

1996

1777

85

957

957

679

ORDERING INFORMATION

S A M P L E NUMBER: AC - 132 - UNV- EB81- U

Rating

Blank=

Standard

NY=NewYork

Rated

ATW-SW4=

Chicago

Rated

Width(2)

Blank=1' Width

Series

AC=Accord Series

Number of Lamps

(Not included)

1=1 Lamp

Wattage (Length)

32=32W T8 (48")

Shielding

Blank=Frosted Acrylic (standard)

Voltage(1)

UNV=Universal Voltage 120-277

Options

GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed

Lamps

L8835=T8 Lamp,

17W and 32W,

3500K

L8841=T8 Lamp,

17W and 32W,

4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens

BallastType

EB8 =T8 Electronic Instant Start.

Total Harmonic Distortion < 10%

No. of Ballast 1 or 2

EB8 /PLUS=T8 Electronic Instant Start.

 

 

 

 

High Ballast Factor >1.13.Total

No. of

Harmonic Distortion < 20%

Ballast

 

1 or 2

 

ER8 =T8 Electronic Program Start. Total Harmonic Distortion < 10%

No. of Ballast 1 or 2

HPT8 Ballast

Ballast

Packaging

U=Unit Pack PALC=Job Pack, in carton

NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) 1' x 4' Accord is not designed for continuous row mount applications.

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88

HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2

HR8_DIM =T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77

HR8 =T8 Electronic Program Start. Ballast Factor .88

HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2

SHIPPING INFORMATION

 

 

 

 

 

 

 

Catalog No.

Wt.

 

 

AC-132T8

22 lbs.

 

 

 

 

Specifications and Dimensions subject to change without notice.

ADF080357

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

08/26/2008 2:44:34 PM

Page 2
Image 2
Cooper Lighting 132T8 Candlepower, Coefficients of Utilization, Zonal Lumen Summary, Luminance Data, Rating Blank=, Width2

132T8 specifications

Cooper Lighting has made a significant mark in the world of lighting solutions, and one of its flagship products is the Cooper Lighting 132T8 commercial fluorescent light fixture. This innovative lighting fixture is specifically designed to provide maximum efficiency and versatility for various applications, including retail spaces, warehouses, and office environments.

One of the standout features of the 132T8 is its energy-efficient design. This fixture utilizes T8 fluorescent lamps, which are known for their lower energy consumption compared to traditional T12 lamps. The 132T8 offers a substantial energy savings potential, making it an ideal choice for businesses looking to reduce operating costs while maintaining bright, vibrant spaces.

Another significant characteristic of the 132T8 is its high lumen output. The fixture delivers excellent brightness while ensuring uniform light distribution. This is particularly important for commercial environments that require consistent lighting to improve visibility and enhance the overall ambiance. With a lumen output that exceeds industry standards, the 132T8 meets the demands of various applications, from task lighting to ambient illumination.

The 132T8 also incorporates advanced technologies that contribute to its overall performance. The fixture is equipped with electronic ballasts, which provide reliable operation and reduced flicker compared to traditional magnetic ballasts. This enhances the visual comfort for occupants and minimizes eye strain, making it an employee-friendly choice for office settings.

Durability and ease of installation are other notable features of the Cooper Lighting 132T8. The fixture is constructed from high-quality materials, ensuring longevity and reliability. Additionally, it is designed for quick and straightforward installation, helping to minimize downtime during setup.

The 132T8 is also highly versatile, available in multiple configurations, including different lengths and lamp wattages, allowing for customization to fit specific needs. This adaptability makes it suitable for various environments, from expansive warehouses to intimate retail spaces.

In conclusion, the Cooper Lighting 132T8 fluorescent light fixture stands out as a top choice for those in search of efficient, durable, and versatile lighting solutions. With its energy-efficient design, high lumen output, advanced technology, and ease of installation, the 132T8 meets the diverse needs of modern commercial spaces while promoting sustainability and operational efficiency.