Cooper Lighting 510 specifications Specifications and Dimensions subject to change without notice

Models: 510

1 2
Download 2 pages 57.23 Kb
Page 2
Image 2
P408ICAT MV4MR E4MR E4MRCB

P408ICAT MV4MR E4MR E4MRCB

Photometric Results

Spacing Criterion = .6 Efficiency = 77.0%

Test No. P11086

Platform = P4

Element = E4MRH

Lumens = 800

Lamp = Q50MR16C/FL/40

50W

MR16

Candlepower Distribution

 

Downlight

 

 

 

90°

 

 

75°

500

 

 

 

 

60°

1000

 

45°

1500

 

 

15°

30°

Cone of Light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

FC

 

 

CB

 

 

 

 

 

7'

29

6.3'

8'

23

7.2'

9'

18

8.1'

10'

14

9.0'

12.5'

9

11.3'

 

 

 

 

 

Candelas

Vertical

CD

Angle

 

 

 

90

0

85

0

75

0

65

1

55

1

45

9

35

51

25

298

15

1047

5

1433

0

1445

Zonal Lumens Summary

 

 

%

%

Zone

Lumens

Lamp

Luminaire

 

 

 

 

0-30

573

71.6

93

 

 

 

 

0-40

607

75.9

98.6

 

 

 

 

0-60

615

76.9

99.9

 

 

 

 

0-90

616

77

100

 

 

 

 

90-180

0

0

0

 

 

 

 

0-180

616

77

100

 

 

 

 

Coefficients of Utilization

Ceiling

70 50 30 10

70 50 30 10

50 30 10

50 30 10

 

50 30 10

0

Wall %

 

 

 

 

 

 

 

 

 

Zonal cavity method -- floor reflectance = 20%

 

 

RCR

 

 

 

0

91 91 91 91

89 89 89 89

85 85 85

82 82 82

 

78 78 78

77

1

88 86 85 83

86 85 83 82

82 80 79

79 78 77

 

76 75 75

74

2

85 82 79 77

83 80 78 76

78 76 75

76 74 73

 

74 73 72

70

3

82 78 75 72

80 77 74 72

75 72 71

73 71 69

 

71 70 68

67

4

79 74 71 68

77 73 70 68

72 69 67

70 68 66

 

69 67 66

65

5

76 71 67 65

75 70 67 64

69 66 64

68 65 63

 

67 65 63

62

6

73 68 64 62

72 67 64 62

66 63 61

65 63 61

 

64 62 60

59

7

71 65 62 59

70 65 61 59

64 61 59

63 60 58

 

62 60 58

57

8

68 63 59 57

68 62 59 56

61 58 56

61 58 56

 

60 58 56

55

9

66 60 57 54

65 60 57 54

59 56 54

59 56 54

 

58 56 54

53

10

64 58 55 52

63 58 54 52

57 54 52

57 54 52

 

56 54 52

51

.

Photometric Results

Spacing Criterion = .4 Efficiency = 75.4%

Test No. P11084

Platform = P4 Element = E4MRH Lumens = 884

Lamp = 50MR16C/NFL/25

50W

MR16

Candlepower Distribution

 

Downlight

 

 

 

90°

 

 

75°

900

 

 

 

 

60°

1800

 

45°

2700

 

 

15°

30°

Cone of Light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

FC

 

 

CB

 

 

 

 

 

8'

42

5.6'

9'

33

6.3'

10'

27

7.0'

13'

16

9.1'

15'

12

10.5'

 

 

 

 

 

Candelas

Vertical

CD

Angle

 

 

 

90

0

85

0

75

0

65

0

55

1

45

8

35

58

25

228

15

1062

5

2479

0

2660

Zonal Lumens Summary

 

 

%

%

Zone

Lumens

Lamp

Luminaire

 

 

 

 

0-30

624

70.6

93.6

 

 

 

 

0-40

658

74.5

98.8

 

 

 

 

0-60

666

75.3

99.9

 

 

 

 

0-90

667

75.4

100

 

 

 

 

90-180

0

0

0

 

 

 

 

0-180

667

75.4

100

 

 

 

 

Coefficients of Utilization

Ceiling

70 50 30 10

70 50 30 10

50 30 10

50 30 10

 

50 30 10

0

Wall %

 

 

 

 

 

 

 

 

 

Zonal cavity method -- floor reflectance = 20%

 

 

RCR

 

 

 

0

90 90 90 90

88 88 88 88

84 84 84

80 80 80

 

77 77 77

75

1

87 85 84 82

85 83 82 81

80 79 79

78 77 76

 

75 75 74

73

2

84 81 79 77

82 80 78 76

77 76 74

75 74 73

 

73 72 71

70

3

81 77 75 72

80 76 74 72

75 73 71

73 71 70

 

71 70 69

68

4

78 74 71 69

77 73 71 69

72 70 68

71 69 67

 

69 68 66

65

5

76 71 68 66

75 71 68 66

70 67 65

68 66 65

 

67 66 64

63

6

74 69 66 63

73 68 65 63

67 65 63

66 64 62

 

66 64 62

61

7

72 67 63 61

71 66 63 61

65 63 61

64 62 60

 

64 62 60

59

8

69 64 61 59

69 64 61 59

63 61 59

63 60 58

 

62 60 58

57

9

68 62 59 57

67 62 59 57

61 59 57

61 58 57

 

60 58 56

56

10

66 61 57 55

65 60 57 55

60 57 55

59 57 55

 

59 57 55

54

Specifications and Dimensions subject to change without notice.

ADI060704

IRiS • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

04/30/2008 10:17:33 AM

Page 2
Image 2
Cooper Lighting 510 Specifications and Dimensions subject to change without notice, P408ICAT MV4MR E4MR E4MRCB