NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH080511

EPL ENVOY

ORDERING INFORMATION

SAMPLE NUMBER: EPL-175-MP-MB-MT-TG-AP-L-EM/SC

EPL

Product Family
EPL=Envoy Parking
Garage Luminaire
Standby + Egress
Options (See Below)
Colors (add as suffix/must specify)
AP=Grey
BZ=Bronze
BK=Black
WH=White
Lamp Wattage
MH 1
175=175W
MP 2
70=70W
100=100W
150=150W
175=175W
200=200W
HPS
70=70W
100=100W
150=150W
Voltage 5
120=120V
208=208V
240=240V
277=277V
480=480V
DT=Dual-Tap 6
MT=Multi-Tap 6
TT=Triple-Tap 6
Distribution
RD=Round
SQ=Square
TG=Rectangular
Options (add as suffix) 7
CD=Concentrated
Downlight (Restricts
Uplight 360°) 8
CT=Conduit Taps (Qty (2) 3/4" NPSM) 9
F=Single Fuse (Specify 120, 277 OR 347 in
"Voltage" column).
FF=Double Fuse (Specify 208, 240 OR 480 in
"Voltage" column)
HA=40° C Ambient 10
HL=Hi/Low Dimming 11
L=Lamp Included, HID
LC=Lamp Included, Compact Fluorescent
LQ=Lamp Included, Quartz Halogen DCB
PH=Upper Polycarbonate Lens (Near Aluminum
Back Housing)
PL=Lower Polycarbonate Lens
QD=Quick Disconnect(s) (between reflector
cover/electrical housing)
TMB=Trunnion Mount with Connection Box
(some assembly required)
TMC=Trunnion Mount with Power Cord
(some assembly required)
TR=Tamper Resistant (Torx T15 CPR)
WL=24" Lead Wires
Accessories 25 (order
separately/replace XX with color
designation)
EPL/PBG-XX=Balanced Pendant
Box/Bird Guard
EPL/WM-XX=Wall Mount Arm 26
EPL/HS=House Side Shield Up and
Downlight 120° Coverage
(HID Lamps Only) 27
EPL/HSCF=House Side Shield Up
and Downlight 120°
Coverage (CF Lamps
Only) 27
EPL/DLS=Drive Lane Shield 28
VRBT15=T15 Torx CPR Tamper
Resistant Driver Bit
VRST15=T15 Torx CPR Tamper
Resistant Screwdriver
EPL/TL=Task Light Field Install Kit
for 120V MR16 lamp (GU10
Base]
EPL/TL12V=Task Light Field Install
Kit for 12V MR16 lamp
(GU5.3 Base)
Lamp Type
MH=Metal Halide
MP=Pulse Start Metal Halide
HPS=High Pressure Sodium
CF=Compact Fluorescent
QL=Induction
Ballast Type
MB=Magnetic 3
EB=Electronic 4
NOTES: 1 Metal Halide lamps with probe start circuit. 2Pulse Start Metal Halide circuit includes igniter. 3HID lamps only. 4Must specify voltage. EB standard on CF. Available integrally in HID 100w MP (max) and 85w QL. HID
availability may vary by lamp source, wattage and voltage. For HID wattages higher than 100w, remote mount ballast possible within 5 feet of unit. Consult customer service. 5Product also available in non-US
voltages and 50Hz for international markets. Must specify voltages for battery packs. Consult your customer service representative for availability and ordering information. 6Dual tap ballast is 120/277V wired 277V.
Multi-tap ballast is 120/208/240/277V wired 277V. Triple tap ballast is 120/277/347 wired 347V. 7Add as suffix in order shown. 8Requires option PL for use in 40°C application with HID lamps 175-200w. 9CT option
required for through branch wiring. Through branch wiring is not available with specific configurations including HID CF egress options and fixtures with integral battery pack. 10 Not available with 85w QL and
options using CF lamp sources. Requires option PH on 200-175w HID. 11 Available in 150-200w MP, 175w MH and 70-150w HPS. Operates on 24VDC type output control module. Circuit relay board is mounted
internal to fixture housing with leads exiting back. Requires low voltage wires to control module to be routed in conduit. 12 For use with HID primary lamp only. Quartz lamp 100w maximum. 13 For use with 175w
(max) or less HID primary lamp only. Uses (2) 4 pin CF lamps. CF minimum starting temperature 0°F (-18°C). Remote battery option requires “CT” option. 14 For use with 150w (max) or less HID primary lamp only.
Uses (2) 18w 4 pin CF lamps. Battery rated minimum 32°F/ 0°C. Specify 120 or 277v in "VOLTAGE" column. 15 For use with 168, 126, 84 CF units only. Requires option “CT”. Battery supplied by others. Standby lamp
combination wired by others. 16 For use with 168, 126, 84 CF units only. Battery rated minimum 32°F/ 0°C. Specify 120 or 277v in "VOLTAGE" column. 17 For use with 168, 126, 84 CF units only. Battery rated minimum
-4°F/ -20°C. Specify 120 or 277v in "VOLTAGE" column. 18 For use with 168 CF only. 19 For use with 126 CF only. 20 For use with 84, 114, or 140 CF only. 21 Task Light(s) with separate leads through back of fixture.
Specify TL location by adding to back of option logic (ex.2TLA1A2)-see diagram. Some assembly required, order lamps separately. 22 For use with HID lamps only. Task Light(s) supplied wired to relay. Specify TL
location by adding to back of option logic (ex.2TLA1A2)-see diagram. Some assembly required, order lamps separately. 23 Task Light(s) supplied with separate leads through back of fixture for connection to 12v
circuit or battery system. Specify TL location by adding to back of option logic (ex.2TLA1A2)-see diagram. Some assembly required, order lamps separately. 24 Task Light max quantity (1), supplied with transformer.
Specify TL location by adding to back of option logic (ex.2TLA1A2)-see diagram. Some assembly required, order lamps separately. 25 Order separately, replace XX with color suffix 26 Luminaires require option (WL),
24" Lead Wires. 27 Order additional shield set for more coverage (ex. 2 sets for 180° shielding) Maximum of 2 sets total. 28 Placed towards side of oncoming traffic for 60° shielding coverage. Order (2) for 2-Way
traffic lanes. 29 Some options and accessories are not available in all configurations. Consult your customer service representative for ordering information.
Standby + Egress Lamp Options
T4 Quartz Halogen + Compact Fluorescent Egress Options (For use with HID as primary
lamp source)
Q=Quartz Restrike (hot restrike only, 120v T4 DCB quartz lamp) 12
EM=Quartz Time Delay (hot and cold restrike, 120v T4 DCB quartz lamp) 12
EM/SC=Emergency Separate Circuit (120v T4 DCB quartz lamp) 12
__CFSC=CF (1) Separate Circuit (Specify 52, 64 or 84, supplied with
120-277v electronic ballast) 13
__CFHR=CF Hot Restrike Relay (Specify 52, 64 or 84, supplied with
120-277v electronic ballast) 13
__CFTR=CF Time Delay Relay (Hot and Cold Restrike) (Specify 52, 64 or
84, supplied with 120-277v electronic ballast) 13
CFRB=CF Remote Battery Pack, sockets accommodate 26-42w CF lamps (Battery Pack
specified/supplied/wired by Others) 13
36CFIB=CF Integral Battery Pack operates (2) 18w CFL 14
CFRBT=CF Remote Battery Pack with Time Delay Relay, sockets accommodate 26-42w CF
lamps (Battery Pack specified/supplied/wired by Others) 13
36CFIBT=CF Integral Battery Pack operates (2) 18w CFL with
Time Delay Relay 14
Compact Fluorescent Egress Options (For use with CF as primary lamp source)
RBP=Remote Battery Pack, sockets accommodate 26-42w CF lamps
(CF units only; Battery Pack specified/supplied/wired by Others) 15
42IBP=Integral Battery Pack, (1) 42w CF lamp standby 16
42ICB=Integral Cold Weather Battery Pack, (1) 42w CF lamp standby 17
4CF3=4 CF lamps wired as 3 independent circuits, 3 electronic ballasts (2 lamps/1 lamp/1
lamp) 18
4CF2=4 CF lamps wired as 2 independent circuits, 2 electronic ballasts (2 lamps/2 lamps) 18
3CF2=3 CF lamps wired as 2 independent circuits, 2 electronic ballasts (2 lamps/1 lamp) 19
2CF2=2 CF lamps wired as 2 independent circuits, 2 electronic ballasts (1 lamp/1 lamp) 20
MR16 Quartz Halogen Egress Options (For use with HID or CF as primary lamp source)
TL__=Task Light 120v MR16 (GU10 Twist Lock Base) 21
2TL__=(2) Task Lights 120v MR16 (GU10 Twist Lock Base) 21
TLQ__=Task Light 120v MR16 wired to Hot Restrike Relay (GU10 Twist Lock Base) 22
2TLQ__=(2) Task Lights 120v MR16 wired to Hot Restrike Relay (GU10 Twist Lock Base) 22
TLEM__=Task Light, 120v MR16 wired to Time Delay Relay (GU10 Twist Lock Base) 22
2TLEM__=(2) Task Lights, 120v MR16 wired to Time Delay Relay (GU10 Twist Lock Base) 22
TL12V__=Task Light, 12v MR16 (GU5.3 Bi-Pin Base) 23
2TL12V__= (2) Task Lights, 12v MR16 (GU5.3 Bi-Pin Base) 23
TL__MR__=Task light with transformer (GU5.3 Bi-Pin Base, specify 50 or 75w lamp,
specify 120 or 277v transformer) 24
CF
84= (2) 42W
114= (2) 57W
126= (3) 42W
140= (2) 70W
168= (4) 42W
Induction
85= 85W
8 3/8"
[213mm]
Adustable to
13 1/4"
13 1/8"
[334mm]
3 7/16" [88mm]
16 5/8"
[423mm]

PENDANT BOX/BIRD GUARD (PBG)TRUNNION-MOUNT (TMB) WALL MOUNT (WM)

20 7/16" [519mm]
13 15/16"
[354mm]
4 1/16"
[104mm]