PHOTOMETRICS

 

 

 

 

 

 

 

 

2HB

2HB-454T5-UPL

Candela

 

 

2HB-454T5-G-UPL

Candela

 

 

Electronic Ballasts

 

 

 

 

Electronic Ballasts

 

 

 

 

(4) F54T5/830 HO

Angle

Along II

45°

Across

(4) F54T5/830 HO

Angle

Along II

45°

Across

lamps

0

5108

5108

5108

lamps

0

5064

5064

5064

5

5058

5272

5533

5

5041

5072

5100

4400 lumens

4400 lumens

10

4983

6118

7612

10

4982

5085

5176

Spacing criterion:

15

4860

7745

8477

Spacing criterion:

15

4885

5092

5168

(II) 1.2 x mounting

20

4687

8179

7737

(II) 1.3 x mounting

20

4745

5015

5073

25

4466

7661

6119

25

4565

4870

4906

height, ( ) 1.2 x

height, ( ) 1.4 x

30

4197

6528

4015

30

4347

4667

4699

mounting height

35

3888

5019

2272

mounting height

35

4094

4407

4514

Efficiency 92.7%

40

3535

3222

2136

Efficiency 99.3%

40

3807

4118

4365

Test Report:

45

3150

1901

2143

Test Report:

45

3487

3841

4206

50

2729

1737

2136

50

3135

3588

4004

2HB454T5UPL.IES

55

2285

1672

2121

2HB454T5G.IES

55

2752

3322

3741

LER =69

60

1836

1601

2128

LER =74

60

2339

3025

3417

65

1397

1533

1993

65

1895

2667

2950

Yearly Cost of 1000

Yearly Cost of 1000

70

975

1464

1606

70

1426

2265

2283

lumens, 3000 hrs at

75

600

1124

1553

lumens, 3000 hrs

75

953

1619

1981

.08 KWH = $3.48

80

302

968

1189

at .08 KWH = $3.23

80

516

1214

1333

85

92

432

317

85

148

436

308

 

 

 

90

2

10

11

 

90

0

0

0

C o effi c i e n t s of Utilization

 

Coefficients of Utilization

 

 

 

 

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

50%

 

 

30%

 

 

10%

 

0%

 

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

109

109

109

109

106

106

106

106

101

101

101

96

96

96

91

91

91

89

 

1

 

101 97

93

90

98

94

91

88

90

87

85

85

83

81

81

80

78

76

 

2

 

93

86

80

75

90

84

78

74

80

75

72

76

73

69

73

70

67

65

 

3

 

85

77

70

64

83

75

69

63

72

66

62

69

64

60

66

62

59

57

 

4

 

79

69

61

56

77

67

60

55

64

59

54

62

57

53

60

55

52

50

 

5

 

73

62

54

48

70

60

53

48

58

52

47

56

50

46

54

49

45

43

 

6

 

67

56

48

42

65

55

47

42

53

46

41

51

45

41

49

44

40

38

 

7

 

62

51

43

38

61

50

43

37

48

42

37

46

41

36

45

40

36

34

 

8

 

58

46

38

33

56

45

38

33

44

37

33

42

36

32

41

36

32

30

 

9

 

54

42

34

29

52

41

34

29

40

33

29

38

32

38

37

32

28

26

 

10

 

50

38

31

26

49

37

31

26

36

30

26

35

29

25

34

29

25

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Typical VCP Percentages

 

 

 

 

 

 

 

 

Height Along

Height Across

Zone

Lumens

%Lamp

%Fixture

Room Size (Ft.)

8.5’

10.0’

8.5’

10.0’

0-30

5533

31.4

33.9

 

20 x 20

45

51

35

46

0-40

8327

47.3

51.0

 

30 x 30

36

41

23

30

0-60

12541

71.3

76.9

 

30 x 60

33

36

16

18

0-90

15612

88.7

95.7

 

60 x 30

33

38

26

33

0-180

16318

92.7

100.0

 

60 x 60

29

32

19

19

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

 

50%

 

30%

 

 

10%

 

0%

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

118

118

118

118

115

115

115

115

110

110

110

106

106

106

101

101

101

99

 

1

 

108

103 99

95

105

101 97

93

96

93

90

93

90

87

89

87

85

83

 

2

 

98

89

82

77

95

87

81

76

84

79

74

81

76

72

78

74

71

68

 

3

 

89

78

70

64

87

77

69

63

74

67

62

71

66

61

69

64

60

58

 

4

 

81

69

60

53

79

68

60

53

65

58

52

63

57

52

61

55

51

49

 

5

 

74

61

51

45

72

60

51

44

57

50

44

55

49

43

54

48

43

41

 

6

 

68

54

45

38

66

53

44

38

51

43

38

50

43

37

48

42

37

35

 

7

 

62

48

39

33

61

48

39

33

46

38

33

44

38

32

43

37

32

30

 

8

 

57

43

34

28

56

43

34

28

41

33

28

40

33

28

39

32

28

26

 

9

 

53

39

30

24

51

38

30

24

37

29

24

36

29

24

35

28

24

22

 

10

 

49

35

27

21

48

35

27

21

34

26

21

33

26

21

32

25

21

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Typical VCP Percentages

 

 

 

 

 

 

 

 

Height Along

Height Across

Zone

Lumens

%Lamp

%Fixture

Room Size (Ft.)

8.5’

10.0’

8.5’

10.0’

0-30

4134

23.5

23.7

 

20 x 20

30

38

23

31

0-40

6882

39.1

39.4

 

30 x 30

24

27

17

21

0-60

12836

72.9

73.5

 

30 x 60

22

24

14

15

0-90

17469

99.3

100.0

 

60 x 30

24

28

21

24

0-180

17469

99.3

100.0

 

60 x 60

22

23

17

16

Modular F-Bay Power Supply

Cooper Lighting’s F-Bay Modular Power Supply option allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixtures power supply allows servicing without turning off all the fixtures disrupting occupants. F-Bay Modular Power Supply is a time

saver in installation – simply plug & power.

1

2

 

 

 

 

No internal fixture

Modular Motion Sensor Option

1. Modular Power Supply Receptacle supplied

mounted into fixture Access Plate.

access required for

supplied with Mounting Box and

2. Modular Power Cord & Plugs in 120, 277, 347,

installation or

Modular Power Supply Receptacle.

disconnecting power.

 

& 480V configurations for easy plug & power

 

into existing supply.

Code Compliance

UL/cUL Certified for Make/Break under load (UL2549)

Meets NEC requirements for ballast disconnect (NEC 410.73G)

Allows for addition of Occupancy Sensor without hard connections

Receptacles complete with insulating dustcap

Specifications and Dimensions subject to change without notice.

ADF023035

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

08/02/2008 1:17:50 PM

Page 2
Image 2
Cooper Lighting 901 specifications 2HB-454T5-UPL, 2HB-454T5-G-UPL, 2HB454T5UPL.IES, 2HB454T5G.IES

901 specifications

Cooper Lighting 901 is a sophisticated lighting fixture designed to elevate both functionality and aesthetics in various indoor environments. Focusing on efficiency, resilience, and versatility, this fixture has earned its place as a preferred choice for architects, designers, and facility managers.

One of the standout features of the Cooper Lighting 901 is its energy efficiency. The design incorporates advanced LED technology, which significantly reduces energy consumption while delivering high-quality illumination. With a lumen output that can reach up to 10,000 lumens, the 901 is ideal for larger spaces such as warehouses, retail stores, and even educational institutions, providing ample light without spiking energy costs.

The durability of the Cooper Lighting 901 is another compelling aspect. Constructed with robust materials, it withstands varying environmental conditions, making it suitable for both indoor and outdoor applications. With an IP rating that ensures resistance to dust and moisture, the fixture is perfect for challenging environments, ensuring longevity and lower maintenance costs over time.

Another notable characteristic is its versatility in terms of design and installation. The 901 can be mounted in multiple ways, including recessed, surface-mounted, or pendant formats, adapting seamlessly to the architectural demands of any space. Furthermore, it comes in various color temperatures, ranging from warm white to cool daylight, enabling users to customize the ambiance according to their preferences or specific needs.

The integration of smart technology is a key aspect of the Cooper Lighting 901. It is compatible with advanced control systems, including dimming and programmable settings, allowing for dynamic lighting scenarios. This not only enhances energy savings further but also allows users to create tailored environments for different activities or moods.

In conclusion, the Cooper Lighting 901 exemplifies the convergence of innovation and practicality in modern lighting solutions. With features that promote energy efficiency, durability, versatility, and smart technology compatibility, it stands as a leading choice for those looking to enhance illuminated spaces while being environmentally conscious. Whether for commercial, industrial, or educational setups, the 901 is engineered to deliver superior performance and reliability, embodying the future of lighting solutions.