Cooper Lighting 901 Catalog Numbering System, Ordering Information, Number of, Circuit Wired

Models: 901

1 3
Download 3 pages 62.71 Kb
Page 3
Image 3
ORDERING INFORMATION

ORDERING INFORMATION

S A M P L E N U M B E R : 2 HB - 432 - A- UNV- EB82/PLUS - UPL- U

Width

2=24"

Series

HB=High Bay

Mounting Arrangement

Blank=Stand Alone

R=Continuous Row Mount

No. of Lamps

4=4 Lamps

Lamp Type

32=32W T8 Lamps (48")

28T5=28W T5 Lamps (48")

54T5=54W T5HO Lamps (48")

Distribution

Blank=Medium (Specular Aluminum)

G=Wide (High Reflectance White)

Shielding (12)

Blank=None

A=Prismatic Acrylic Lens & Doorframe

WG=Wireguard & Doorframe

A/WG=Acrylic Lens, Wireguard & Doorframe

CL=Clear Acrylic Lens & Doorframe

CL/WG=Clear Lens, Wireguard & Doorframe

CL/DWG=Clear Lens, Drop Wireguard & Doorframe

DWG=Drop Wireguard & Doorframe

A/DWG=Acrylic Lens, Drop Wireguard & Doorframe

Voltage(2)

UNV=Universal 120/277

Voltage

UNC=Universal 347/480

Voltage

120V=120 Volt

277V=277 Volt

347V=347 Volt

480V=480 Volt

Options

Lamps Installed

L8830=T8 Lamp, 85CRI 3000K

L8835=T8 Lamp, 85CRI 3500K

L8841=T8 Lamp, 85CRI 4100K

L8850=T8 Lamp, 85CRI 5000K

L5830=T5 Lamp, 85CRI 3000K

L5835=T5 Lamp, 85CRI 3500K

L5841=T5 Lamp, 85CRI 4100K

L5850=T5 Lamp, 85CRI 5000K

GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed(2)

BallastType

T8 Systems

EB8 =T8 Electronic Instant Start.(4) Total Harmonic Distortion < 10%

No. of Ballast 1 or 2

EB8 /PLUS=T8 Electronic Instant Start.(4)

 

 

 

 

High Ballast Factor >1.15.Total

No. of

Harmonic Distortion < 10%

Ballast

 

1 or 2

 

ER8 =T8 Electronic Program Rapid Start.(4)

 

 

 

Total Harmonic Distortion < 10%

 

No.

of Ballast

 

1 or 2

 

ER8 /PLUS=T8 Electronic Program Start.(4)

 

 

 

 

High Ballast Factor >1.15.Total

 

No. of

Harmonic Distortion < 10%

 

Ballast

 

 

 

1 or 2

 

T5 Systems

EBT =T5 Linear Electronic Program Rapid Start.(3) Total Harmonic Distortion < 10%

No. of Ballast 1 or 2

EHT =T5 Linear Electronic Program Start High

Ambient.(7) (8) (12)

Total Harmonic Distortion < 10%

No. of Ballast 1 or 2

DIM=Consult Factory(13)

 

 

 

 

 

Options

Packaging

NUA=No uplight apertures

U=Unit Pack

in housing. (Cannot be

PAL=Palletized

combined w/UPL)

Out of Carton

UPL=Uplight Apertures

PALC=Palletized

PI/CPI=Plug-In (1, 2 or 3)(9)

In Carton

see ordering information

 

 

 

below

TILW=Tandem Inline Wiring

MWS=Modular Wiring System

MS=Aisle Coverage Motion Sensor(5) MSO=360˚ Coverage Motion Sensor(5)

C3=3' Power Cord

C6=6' Power Cord

G2=Gasketed Door (Requires Selection of Lensed Doorframe)

MP=Modular Power Receptacle(1)

PC3-=3' Power Cord & Plug (Specify Voltage)(2) PC6-=6' Power Cord & Plug (Specify Voltage)(2) TAP=Top Access Plate(11)

TCBP=Top Connector Box Plate(6)

Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks(10)

TCB=Top Connector Box RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop

HB-SPS=Single Point Cable Kit (13" Drop Length) GRIPPLE-Y-=Y Mounting Toggle, #2 Cable (Specify 10' or 30')

MC3=3' Modular Power Cord

NOTES: (1)Requires use of MC or MPC cord accessories, specify voltage for plugs. (2)Voltage must be specified when ordered with plugs, motion or emergency ballasts. (3)EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C) in open uplight configuration. (4)ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configuration. (5)Specify voltage. (6)For use with Top Connector Box options. See accessories. (7)2 lamp ballast configurations only in UNC versions. (8)EHT/HT5/HCT5 ballast systems suitable for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less lens option. (9)Cannot be combined with cord or cord & plug. See PI ordering information below. (10)Not for use in high abuse applications such as gymnasiums.(11)For use withT8 system with a maximum of two ballasts (including Emergency ballast). (12)Lensed 6-LampT5HO luminaire must use High Ambient ballast option (EHT). (13)Dimming ballast must be specified at time of order.

MPC3=3' Modular Power Cord & Plug

(Specify Voltage)

MC6=6' Modular Power Cord

MPC6=6' Modular Power Cord & Plug

(Specify Voltage)

MMS-CPD1200H=Aisle Motion Sensor, Box,

Modular Power Receptacle (120-277V)

MMS-CPD500H=360° Motion Sensor, Box,

Modular Power Receptacle (120-277V)

 

 

 

Doorframes (for field installation)(12)

 

 

 

2HB-4-A-W/FRM PK=Prismatic Acrylic Lens & Frame (2HB)

 

 

 

2HB-FRM/CL PK=Clear Acrylic Lens & Frame (2HB)

 

 

 

2HB-FRM/WG PK=Wireguard & Frame (2HB)

 

 

 

2HB-FRM/CL/WG PK=Clear Acrylic Lens, Frame and Wireguard (2HB)

 

 

 

2HB-FRM/LENS/DROPWG PK=Drop Wireguard, Prismatic Lens and Frame

 

 

 

(2HB)

 

 

 

2HB-FRM/LENS/DROPWG PK=Drop Wireguard, Prismatic Acrylic Lens and

 

 

 

Frame (2HB)

 

 

 

2HB-FRM/DROPWG PK=Drop Wireguard and Doorframe

PI OPTION ORDERING INFORMATION

 

 

 

 

 

 

Catalog Number

Number of

Circuit Wired

Catalog Numbering System

Suffix

Circuits

To Ballast

The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the

PI 1 BLK

1

Black

sections together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows:

PI-1= One Circuit - 2 Wires: one black, one white

PI 2 BLU

2

Blue

PI 2 BLK

2

Black

PI-2= Two Circuits - 3 Wires: one black, one blue, one white

PI 3 RED

3

Red

PI-3= Three Circuits - 4 wires: one black, one blue, one red, one white

When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit.

PI 3 BLU

3

Blue

All wiring to external feeds, using cord or cord & plug, are responsibility of installing licensed contractor.

PI 3 BLK

3

Black

Cord and cord & plug sets must be ordered separately if PI option is chosen.

 

 

 

P I 1 - S i n g l e C i rc u i t P l u g - I n

S A M P L E N U M B E R : P I 1 B L K - W G

P I 2 - Two C i rc u i t P l u g - I n

S A M P L E N U M B E R : P I 2 B L K - W G

P I 3 - T h re e C i rc u i t P l u g - I n

S A M P L E N U M B E R : P I 3 B L K - W G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PI1= Single

 

 

 

 

NG= No Ground (ground

 

Circuit

 

 

 

 

provided by fixture body)

 

 

 

 

 

 

 

WG= With Ground

 

BLK=Black Hot

 

(separate ground wire

 

 

 

 

 

 

 

 

in harness)

For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PI2= Two

 

 

 

 

 

Leave Blank=Single

 

Circuit

 

 

 

 

 

Neutral

 

 

 

 

 

 

 

 

2NEU=Two Neutrals

 

BLK=Black Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

BLU=Blue Hot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NG= No Ground (ground

 

 

 

 

 

 

 

provided by fixture body)

Leave Blank=Single

 

 

 

 

WG= With Ground (separate

Neutral

 

 

 

 

ground wire in harness)

/WHT=White Neutral

 

 

 

 

 

 

 

 

 

/GRY=Gray Neutral

 

 

 

 

 

 

 

 

 

PI3= Three

Circuit

BLK=Black Hot

BLU=Blue Hot

RED=Red Hot

Leave Blank=Single

Neutral

/WHT=White Neutral

/GRY=Gray Neutral

Leave Blank=Single Neutral

2NEU=Two Neutrals

NG= No Ground (ground provided by fixture body)

WG= With Ground (separate ground wire in harness)

SHIPPING INFORMATION

Catalog No.

Wt.

2HB-432-G-120V-UPL

22 lbs.

2HB-454T5-120V-UPL

22 lbs.

 

 

 

 

Specifications and Dimensions subject to change without notice.

ADF023035

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

08/02/2008 1:17:50 PM

Page 3
Image 3