Semi-recessed fixtures shown without thermal protectors

Installation Instructions

Sheet 3 of 4

 

 

 

Vault w/ visor

 

C-Scroll w/ visor

 

Roundel w/ visor

These installation instructions are valid with the above Ametrix styles.

Small, INDOOR

SRI

(Semi-Recessed, Integral ballast)

Visor and Non-Visor

Warning: Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically.

4.

Securing the fixtures with safety wire

(both ceiling grid and drywall)

Safety wire (by others)

Fixture housing

1.After securing fixture housing to ceiling structure using provided brackets, reinforce fixture using safety wire(by others).

2.Using all four tabs located on corners of fixture housing, tie off fixture to structure using safety wire(by others).

5.

 

Wiring the fixture

 

(both ceiling grid and drywall)

#10-32 x3/8"

 

Pan head screw

Choose appropriate cover plate

(2x)

 

depending on location of power

 

source.

Ceiling surface

Conduit Nut (by others)

Conduit fitting (by others)

Cover plate

Conduit (by others)

1.If applicable, replace ceiling tile with fixture secured back into ceiling. Remove adjacent tile from ceiling to facilitate wiring.

2.Depending on location of power source, loosen #10-32 x3/8" Pan head screws and remove appropriate cover plate and knock out appropriate hole.

3.Using conduit fitting and washer, secure conduit to cover plate.

4.Attach appropriate wires and ensure all connections are properly matched.

5.Replace cover plate and secure with #10-32 x3/8" Pan head screws.

ADY071458 REV A (ECN070344)