Cooper Lighting ADY071458 manual Small, INDOOR SRI, Visor and Non-Visor, Installation Instructions

Models: ADY071458

1 4
Download 4 pages 63.1 Kb
Page 2
Image 2
Installation Instructions

Semi-recessed fixtures shown without thermal protectors

Installation Instructions

Sheet 2 of 4

 

 

 

Vault w/ visor

C-Scroll w/ visor

Roundel w/ visor

These installation instructions are valid with the above Ametrix styles.

Small, INDOOR

SRI

(Semi-Recessed, Integral ballast)

Visor and Non-Visor

Warning: Before starting any work ensure that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. Do not mount fixtures vertically.

2.

Securing fixture to ceiling tile

 

#10-32 x3/8"

 

 

Pan head screw

Universal

 

(4x)

bracket

Small, INDOOR Ceiling tile

Visor and Non-VisorSecuring fixture to ceiling tileWiring the fixture3.Replacing brackets on fixture housing3. Securing the fixture in drywall Fixture Manual backgroundManual backgroundManual backgroundManual backgroundassembly

1.If possible, remove ceiling tile from grid to facilitate fixture installation.

2.Using cut out dimensions provided on page four(4), cut appropriate size opening in ceiling tile.

3.Insert fixture assembly into cut out in ceiling tile.

2.

Wiring the fixture

 

 

(drywall)

Conduit from

 

 

 

 

power source.

 

 

(by others)

 

 

Cover plate

 

 

#10-32 x3/8"

 

 

Pan head screws

 

 

(2x)

 

 

Fixture housing

1.Using cut out dimensions provided on page four(4), cut hole into dry wall and feed power wire to hole.

2.After removing fixture head, loosen #10-32 x3/8" Pan head screws and remove cover plate closest to power feed.

3.Knock out appropriate hole for conduit and attach as shown on page three(3).

4.Replace cover plate and secure with #10-32 x3/8" Pan head screws and press fixture housing into hole in drywall.

3.Replacing brackets on fixture housing

(ceiling grid)

#10-32 x 3/8" Pan head screws (4x)Manual background

Universal brackets (2x)

1.Loosely reattach brackets to both sides of fixture housing.

2.Press brackets flush to ceiling tile and secure using #10-32 x 3/8".

3. Securing the fixture in drywall

1/4-20 x1 1/2"Manual background Pan head screwManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Safety wires (by others) (4x)

1.Prior to pushing fixture into hole in drywall, tie off fixture housing to structure using saftey wire(by others) as show on page three(3).

2.Gently push fixture housing into hole and tighten 1/4-20 x 1 1/2" Pan head screw from inside fixture housing to tighten drywall bracket around drywall.

3.Connect appropriate wires from fixture head and ensure all wires are properly matched.

4.Replace fixture head assembly on keyhole screws and tighten.

ADY071458 REV A (ECN070344)

Page 2
Image 2
Cooper Lighting ADY071458 manual Small, INDOOR SRI, Visor and Non-Visor, Installation Instructions, Wiring the fixture