PHOTOMETRICS | GR8 |
|
|
⊥
GR8-232A Electronic Ballast
F32T8/35K lamps 2800 lumens
Spacing criterion:
(II)1.2 x mounting height, (⊥) 1.2 x mounting height
Efficiency 68.2%
Test Report:
GR8232A.IES
LER =
Yearly Cost of 1000 lumens, 3000 hrs at
.08 KWH = $4.14
Coefficients of Utilization
| Effective floor cavity reflectance |
| 20% |
|
|
|
|
|
|
|
| |||||||
rc |
| 80% |
|
| 70% |
|
| 50% |
|
| 30% |
|
| 10% |
| 0% | ||
rw | 70 | 50 | 30 | 10 | 70 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 50 | 30 | 10 | 0 |
RCR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 | 81 | 81 | 81 | 81 | 79 | 79 | 79 | 79 | 76 | 76 | 76 | 73 | 73 | 73 | 70 | 70 | 70 | 68 |
1 | 75 | 73 | 70 | 68 | 74 | 71 | 69 | 67 | 68 | 66 | 65 | 66 | 64 | 63 | 63 | 62 | 61 | 60 |
2 | 70 | 65 | 61 | 58 | 68 | 64 | 60 | 57 | 61 | 58 | 56 | 59 | 57 | 55 | 57 | 55 | 53 | 52 |
3 | 65 | 59 | 54 | 50 | 63 | 58 | 53 | 50 | 56 | 52 | 49 | 54 | 51 | 48 | 52 | 49 | 47 | 46 |
4 | 60 | 53 | 47 | 43 | 58 | 52 | 47 | 43 | 50 | 46 | 43 | 49 | 45 | 42 | 47 | 44 | 42 | 40 |
5 | 55 | 47 | 42 | 38 | 54 | 47 | 41 | 38 | 45 | 41 | 37 | 44 | 40 | 37 | 43 | 39 | 36 | 35 |
6 | 51 | 43 | 37 | 33 | 50 | 42 | 37 | 33 | 41 | 36 | 33 | 40 | 36 | 33 | 39 | 35 | 32 | 31 |
7 | 47 | 39 | 33 | 29 | 46 | 38 | 33 | 29 | 37 | 33 | 29 | 36 | 32 | 29 | 35 | 32 | 29 | 27 |
8 | 44 | 35 | 30 | 26 | 43 | 35 | 29 | 26 | 34 | 29 | 26 | 33 | 29 | 25 | 32 | 28 | 25 | 24 |
9 | 40 | 32 | 26 | 23 | 39 | 31 | 26 | 22 | 30 | 26 | 22 | 30 | 25 | 22 | 29 | 25 | 22 | 21 |
10 | 38 | 29 | 24 | 20 | 37 | 28 | 23 | 20 | 28 | 23 | 20 | 27 | 23 | 20 | 27 | 23 | 20 | 19 |
Zonal Lumen Summary | Typical VCP Percentages |
|
| ||||||
|
|
|
|
|
| Height Along | Height Across | ||
Zone | Lumens | %Lamp | %Fixture | Room Size (Ft.) | 8.5' | 10.0' | 8.5' | 10.0' | |
1322 | 23.6 | 34.6 |
| 20 x 20 | 61 | 64 | 62 | 67 | |
2104 | 37.6 | 55.1 |
| 30 x 30 | 54 | 58 | 54 | 59 | |
3301 | 58.9 | 86.4 |
| 30 x 60 | 45 | 48 | 44 | 47 | |
3821 | 68.2 | 100.0 |
| 60 x 30 | 56 | 60 | 57 | 61 | |
3821 | 68.2 | 100.0 |
| 60 x 60 | 46 | 49 | 45 | 48 |
C a n d l e p o w e r
Angle | Along II | 45o | Across ⊥ |
0 | 1704 | 1704 | 1704 |
5 | 1695 | 1701 | 1699 |
10 | 1674 | 1683 | 1685 |
15 | 1637 | 1650 | 1652 |
20 | 1583 | 1597 | 1595 |
25 | 1511 | 1519 | 1496 |
30 | 1418 | 1405 | 1357 |
35 | 1300 | 1260 | 1199 |
40 | 1158 | 1089 | 1030 |
45 | 988 | 902 | 854 |
50 | 795 | 718 | 677 |
55 | 619 | 550 | 508 |
60 | 462 | 393 | 369 |
65 | 332 | 264 | 272 |
70 | 235 | 175 | 211 |
75 | 167 | 129 | 172 |
80 | 123 | 107 | 132 |
85 | 65 | 60 | 72 |
90 | 0 | 0 | 0 |
ORDERING INFORMATION
Sample Number:
Width
__= 1' width
Trim Type
G=
Series
R8= General Purpose1
T8 Commercial
Troffer
Number of Lamps 2
2= 2 Lamps (Not Included)
Wattage
32= 32W T8 (48")
Shielding
A= # 12 Acrylic Pattern
A125= #12 Pattern Acrylic (.125"
Thickness)
Voltage 3
120V= 120 Volt
277V= 277 Volt
347V= 347 Volt
UNV= Universal Voltage
Options
Ballast Type 3
EB= Electronic Instant Start
ER= T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
DLS= Digital Lighting System Dimming
Lamp Size
8= T8
Number of
Ballasts
1= 1 Ballast
2= 2 Ballast
Options
/PLUS= Higher Ballast Factor >
1.13.Total Harmonic Distortion < 20%
FR= Fire Rated Label
Packaging
U= Unit Pack
GL= Single Element Fuse
GM= Double Element Fuse
Lamps= Lamps Installed
Flex= Flex Installed
Emergency= EM Installed
ACCESSORIES
EQ =
Notes: 1 | An EQ Grid Clip is recommended for all 9/16" ceiling systems. |
2Standard
3Products also available in
4Not Available when specifying emergencies, voltage must be specific
SHIPPING INFORMATION |
|
|
| |
|
|
|
|
|
| Catalog No. | Wt. |
| |
| 19 lbs. | |||
|
|
|
|
|
Specifications and Dimensions subject to change without notice. | ADF031753 |
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 | 11/07/2007 2:05:51 PM |