PHOTOMETRICS

GR8

 

 

GR8-232A Electronic Ballast

F32T8/35K lamps 2800 lumens

Spacing criterion:

(II)1.2 x mounting height, () 1.2 x mounting height

Efficiency 68.2%

Test Report:

GR8232A.IES

LER = FL-58

Yearly Cost of 1000 lumens, 3000 hrs at

.08 KWH = $4.14

Coefficients of Utilization

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

rc

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

81

81

81

81

79

79

79

79

76

76

76

73

73

73

70

70

70

68

1

75

73

70

68

74

71

69

67

68

66

65

66

64

63

63

62

61

60

2

70

65

61

58

68

64

60

57

61

58

56

59

57

55

57

55

53

52

3

65

59

54

50

63

58

53

50

56

52

49

54

51

48

52

49

47

46

4

60

53

47

43

58

52

47

43

50

46

43

49

45

42

47

44

42

40

5

55

47

42

38

54

47

41

38

45

41

37

44

40

37

43

39

36

35

6

51

43

37

33

50

42

37

33

41

36

33

40

36

33

39

35

32

31

7

47

39

33

29

46

38

33

29

37

33

29

36

32

29

35

32

29

27

8

44

35

30

26

43

35

29

26

34

29

26

33

29

25

32

28

25

24

9

40

32

26

23

39

31

26

22

30

26

22

30

25

22

29

25

22

21

10

38

29

24

20

37

28

23

20

28

23

20

27

23

20

27

23

20

19

Zonal Lumen Summary

Typical VCP Percentages

 

 

 

 

 

 

 

 

Height Along

Height Across

Zone

Lumens

%Lamp

%Fixture

Room Size (Ft.)

8.5'

10.0'

8.5'

10.0'

0-30

1322

23.6

34.6

 

20 x 20

61

64

62

67

0-40

2104

37.6

55.1

 

30 x 30

54

58

54

59

0-60

3301

58.9

86.4

 

30 x 60

45

48

44

47

0-90

3821

68.2

100.0

 

60 x 30

56

60

57

61

0-180

3821

68.2

100.0

 

60 x 60

46

49

45

48

C a n d l e p o w e r

Angle

Along II

45o

Across

0

1704

1704

1704

5

1695

1701

1699

10

1674

1683

1685

15

1637

1650

1652

20

1583

1597

1595

25

1511

1519

1496

30

1418

1405

1357

35

1300

1260

1199

40

1158

1089

1030

45

988

902

854

50

795

718

677

55

619

550

508

60

462

393

369

65

332

264

272

70

235

175

211

75

167

129

172

80

123

107

132

85

65

60

72

90

0

0

0

ORDERING INFORMATION

Sample Number: 2GR8-232A-120V-EB81-U

Width

__= 1' width

Trim Type

G= Grid/Lay-in (Standard)

Series

R8= General Purpose1

T8 Commercial

Troffer

Number of Lamps 2

2= 2 Lamps (Not Included)

Wattage

32= 32W T8 (48")

Shielding

A= # 12 Acrylic Pattern

A125= #12 Pattern Acrylic (.125"

Thickness)

Voltage 3

120V= 120 Volt

277V= 277 Volt

347V= 347 Volt

UNV= Universal Voltage 120-2774

Options

Ballast Type 3

EB= Electronic Instant Start

ER= T8 Electronic Program Rapid Start.

Total Harmonic Distortion < 10%

DLS= Digital Lighting System Dimming

Lamp Size

8= T8

Number of

Ballasts

1= 1 Ballast

2= 2 Ballast

Options

/PLUS= Higher Ballast Factor >

1.13.Total Harmonic Distortion < 20%

FR= Fire Rated Label

Packaging

U= Unit Pack

GL= Single Element Fuse

GM= Double Element Fuse

Lamps= Lamps Installed

Flex= Flex Installed

Emergency= EM Installed

ACCESSORIES

EQ = T-Bar Safety Earthquake Clips 1 FCS-XXW-U= Field Installed Flange Kit

Notes: 1

An EQ Grid Clip is recommended for all 9/16" ceiling systems.

2Standard off-center ballast on 3 lamp fixtures.

3Products also available in non-US voltage and freqeuncies for international markets

4Not Available when specifying emergencies, voltage must be specific

SHIPPING INFORMATION

 

 

 

 

 

 

 

 

 

Catalog No.

Wt.

 

 

GR8-232A

19 lbs.

 

 

 

 

 

Specifications and Dimensions subject to change without notice.

ADF031753

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

11/07/2007 2:05:51 PM

Page 2
Image 2
Cooper Lighting CWR-800 specifications Photometrics, Ordering Information, Accessories