Cooper Lighting F-BAY 2HBHD SERIES P H O T O M E T R I C S, 2HBHD-632-CL, 2HBHD-654T5-CL

Models: F-BAY 2HBHD SERIES

1 2
Download 2 pages 14.7 Kb
Page 2
Image 2
P H O T O M E T R I C S

 

 

 

 

 

 

 

 

 

2 H B H D

P H O T O M E T R I C S

 

 

 

 

 

 

 

 

 

2HBHD-632-CL

Candela

 

 

2HBHD-654T5-CL

Candela

 

 

(2) Electronic Ballasts

 

 

 

 

(3) Electronic Ballasts

 

 

 

 

(6) F32T8/TL835

Angle

Along II

45°

Across

(6) F54T5/841HO

Angle

Along II

45°

Across

lamps

0

4538

4538

4538

54W lamps

0

8058

8058

8058

5

4601

4543

4510

5

8298

8229

8014

3000 lumens

4400 lumens

10

4787

4628

4442

10

8281

8222

7894

Spacing criterion:

15

4969

4705

4319

Spacing criterion:

15

7647

8038

7681

(II) 1.2 x mounting

20

4999

4740

4160

(II) 1.0 x mounting

20

6853

7410

7382

25

4938

4685

3958

25

5872

6624

7000

height, () 1.2 x

height, () 1.2 x

30

4514

4559

3711

30

4611

5867

6542

mounting height

mounting height

35

3882

4262

3434

35

3428

4902

6018

Efficiency 68.1%

40

3100

3739

3121

Efficiency 52.9%

40

2751

3736

5440

45

2696

3118

2782

45

2431

2770

4810

Test Report:

Test Report:

50

2392

2414

2420

50

2365

2164

4141

2HBHD632CL.IES

55

2169

1992

2035

2HBHD654T5CL.IES

55

2227

1806

3435

LER =75

60

2008

1643

1638

LER =40

60

1957

1671

2715

65

1762

1377

1235

65

1577

1388

1998

 

 

Yearly Cost of 1000

70

1400

1131

843

Yearly Cost of 1000

70

1358

1043

1309

lumens, 3000 hrs at

75

875

772

485

lumens, 3000 hrs

75

918

734

707

.08 KWH = $3.22

80

355

360

211

at .08 KWH = $6.03

80

416

394

270

85

77

76

48

85

87

84

48

 

 

 

90

0

0

0

 

90

0

0

0

Coefficients of Utilization

 

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

 

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

81

81

81

81

79

79

79

79

76

76

76

72

72

72

69

69

69

68

 

1

 

75

72

69

66

73

70

68

65

67

65

63

65

63

61

62

61

60

58

 

2

 

68

63

58

55

66

62

58

54

59

56

53

57

54

52

55

53

51

49

 

3

 

62

56

50

46

61

54

50

46

52

48

45

51

47

44

49

46

43

42

 

4

 

57

49

44

39

56

49

43

39

47

42

38

45

41

38

44

40

37

36

 

5

 

53

44

38

34

51

44

38

34

42

37

34

41

37

33

40

36

33

31

 

6

 

49

40

34

30

48

39

34

30

38

33

30

37

33

29

36

32

29

28

 

7

 

45

36

31

27

44

36

30

26

35

30

26

34

29

26

33

29

26

25

 

8

 

42

33

28

24

41

33

27

24

32

27

24

31

27

23

30

26

23

22

 

9

 

40

31

25

21

39

30

25

21

29

25

21

29

24

21

28

24

21

20

 

10

 

37

28

23

19

36

28

23

19

27

23

19

27

22

19

26

22

19

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Typical VCP Percentages

 

 

 

 

 

 

 

 

Height Along

Height Across

Zone

Lumens

%Lamp

%Fixture

Room Size (Ft.)

8.5’

10.0’

8.5’

10.0’

0-30

3768

20.9

30.7

 

20 x 20

35

43

41

46

0-40

6124

34.0

50.0

 

30 x 30

33

34

39

40

0-60

10121

56.2

82.6

 

30 x 60

35

33

40

39

0-90

12258

68.1

91.5

 

60 x 30

39

39

43

42

0-180

12258

68.1

100.0

 

60 x 60

40

36

43

40

O R D E R I N G I N F O R M AT I O N

Coefficients of Utilization

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

 

rw

 

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

70

70

70

70

69

69

69

69

66

66

66

63

63

63

60

60

60

59

 

1

 

65

63

61

59

64

61

59

58

59

57

56

57

55

54

55

54

53

51

 

2

 

60

56

52

49

59

55

51

49

53

50

47

51

48

46

49

47

45

44

 

3

 

55

50

45

42

54

49

45

42

47

44

41

46

43

40

44

42

40

38

 

4

 

51

45

40

36

50

44

40

36

42

39

36

41

38

35

40

37

35

34

 

5

 

47

40

36

32

46

40

35

32

39

35

31

37

34

31

36

33

31

30

 

6

 

44

37

32

28

43

36

32

28

35

31

28

34

31

28

33

30

28

27

 

7

 

41

34

29

26

40

33

29

25

32

28

25

32

28

25

31

27

25

24

 

8

 

38

31

26

23

38

31

26

23

30

26

23

29

26

23

29

25

23

22

 

9

 

36

29

24

21

35

28

24

21

28

24

21

27

23

21

27

23

21

20

 

10

 

34

27

22

19

33

26

22

19

26

22 19

25

22

19

25

21

19

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zonal Lumen Summary

Typical VCP Percentages

 

 

 

 

 

 

 

 

Height Along

Height Across

Zone

Lumens

%Lamp

%Fixture

Room Size (Ft.)

8.5’

10.0’

8.5’

10.0’

0-30

5876

22.3

37.6

 

20 x 20

37

44

39

42

0-40

8802

33.3

56.3

 

30 x 30

34

35

37

37

0-60

13385

50.7

85.7

 

30 x 60

35

33

39

37

0-90

15627

59.2

75.3

 

60 x 30

40

39

42

40

0-180

15627

59.2

100.0

 

60 x 60

40

36

42

39

S A M P L E N U M B E R : 2 HBHD - 654T5 - A- UNV- EBT2

Width 2=24"

Series

HBHD=High Bay

Hose Down

No. of Lamps

4=4 Lamps

6=6 Lamps

Lamp Type

32=32W T8 Lamps (48")

28T5=28W T5 Lamps (48")

54T5=54W T5HO Lamps (48")

Distribution

Blank=Medium (Specular Aluminum) G=Wide (High Reflectance White)

Shielding

A=Prismatic Acrylic Lens &

Aluminum Doorframe

CL=Clear Acrylic Lens &

Aluminum Doorframe

Voltage(1)

UNV=Universal 120/277 Voltage UNC=Universal

347/480 Voltage (T5 linear only)(2) 120V=120 Volt

277V=277 Volt

347V=347 Volt

Options

Lamps Installed

L8830=T8 Lamp, 80CRI 3000K

L8835=T8 Lamp, 80CRI 3500K

L8841=T8 Lamp, 80CRI 4100K

L8850=T8 Lamp, 80CRI 5000K

L5830=T5 Lamp, 80CRI 3000K

L5835=T5 Lamp, 80CRI 3500K

L5841=T5 Lamp, 80CRI 4100K

L5850=T5 Lamp, 80CRI 5000K

GL=Single Element Fuse

GM=Double Element Fuse

Emergency=EM Installed

BallastType(1)

T8 Systems

EB8 =T8 Electronic Instant Start.

Total Harmonic Distortion < 10%

No. of Ballast 1 or 2

EB8 /PLUS=T8 Electronic Instant Start. 2HBHD-632-CL High Ballast Factor >1.13.Total

No. of

Harmonic Distortion < 20%

Ballast

 

1 or 2

 

ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%

No. of Ballast 1 or 2

ER8 /PLUS=T8 Electronic Program Start.

No. of

High Ballast Factor >1.13.Total

Harmonic Distortion < 10%

Ballast

 

1 or 2

 

T5 Systems

EBT =T5 Linear Electronic Program Rapid StartTotal Harmonic Distortion < 10%

No. of Ballast 1, 2 or 3

EHT =T5 Linear Electronic Start High Ambient.(2)

Total Harmonic Distortion < 10% No. of Ballast

1, 2 or 3 DIM=Dimming

 

 

 

 

 

Options

Packaging

C3=3' Power Cord(3)

U=Unit Pack

C6=6' Power Cord(3)

PAL=Pallet Pack

PC3-=3' Power Cord & Plug

PALC=Job Pack

(Specify Voltage)(1), (3)

In Carton

PC6-=6' Power Cord & Plug

 

 

 

(Specify Voltage)(1), (3)

 

 

 

SSF304=Stainless Steel

 

 

 

Housing and Frame, 304 Finish

Accessories (order separately)

EHK=Suspension Mounting Kit (Chain/Gripple not included)(4)

HB-SPS= Single Point Cable kit SCA-48= Stem Set Adjustable 48" length(5) SCF= Stem Set Fixed (Specify length)(5) SCS= Stem Set 45˚ Swivel (Specify length)(5)

S H I P P I N G I N F O R M AT I O N

Catalog No.

Wt.

2HBHD -654T5

44 lbs.

2HBHD-454T5

44 lbs.

NOTES: (1)Voltage must be specified when ordered with plugs, motion or emergency ballasts. (2)2 lamp ballast configurations only in UNC versions. (3)Cord or cord

&plug options only available with pendant mount fixtures. (4)Chain or gripple for EHK must be ordered separately. See mounting. (5)See accessories for ordering information on stem sets.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 8/08

ADF042010

Page 2
Image 2
Cooper Lighting F-BAY 2HBHD SERIES dimensions P H O T O M E T R I C S, 2HBHD-632-CL, 2HBHD-654T5-CL