PHOTOMETRICS

FDI

PHOTOMETRICS

Candlepower Distribution

Candlepower

Zonal Lumen Summary

250

500

750

1000

1250

Test No. 5489

 

 

Deg.

 

 

 

 

 

 

 

 

 

Zone

 

Lumens

%Lamp

%Luminaire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

1027

 

1027

 

0-20

 

356

5.6

 

16.9

 

 

 

 

FDI-240-120V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

1059

 

982

 

0-40

 

1078

16.8

 

51.1

 

 

 

 

Lamp=(2) F40T12RS/

 

 

 

 

 

 

 

 

 

 

 

15

 

1131

 

933

 

0-60

 

1752

27.4

 

83.1

 

 

 

 

 

 

WW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

1077

 

765

 

0-90

 

2081

32.5

 

98.7

 

 

 

 

Lumens=3200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35

 

1017

 

575

 

0-120

 

2108

32.9

 

100.0

 

 

 

 

Efficiency=32.9%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

915

 

388

 

0-180

 

2108

32.9

 

100.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

 

792

 

253

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

466

 

144

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

 

239

 

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

146

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

 

124

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coefficient of Utilization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

80%

 

 

 

 

 

70%

50%

 

30%

 

10%

0%

 

 

 

 

 

 

 

rw

70

50

30

10

50

30

10

50

10

50

10

50

10

0

 

 

 

 

 

 

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

39

39

39

39

38

38

38

36

36

35

35

33

33

33

 

 

 

 

 

 

 

1

 

36

35

34

32

34

33

32

33

31

31

30

30

29

28

 

 

 

 

 

 

 

2

 

33

31

29

27

30

29

27

29

26

28

26

27

25

24

 

 

 

 

 

 

 

3

 

31

28

25

24

27

25

23

26

23

25

22

25

22

21

 

 

 

 

 

 

 

4

 

29

25

22

20

25

22

20

24

20

23

20

22

19

19

 

 

 

 

 

 

 

5

 

26

22

20

18

22

19

17

21

17

21

17

20

17

16

 

 

 

 

 

 

 

6

 

24

20

17

15

20

17

15

19

15

19

15

18

15

14

 

 

 

 

 

 

 

7

 

22

18

16

14

18

15

14

17

13

17

13

16

13

13

 

 

 

 

 

 

 

8

 

21

16

14

12

16

14

12

16

12

15

12

15

12

11

 

 

 

 

 

 

 

9

 

19

15

12

10

15

12

10

14

10

14

10

13

10

10

 

 

 

 

 

 

10

18

14

11

09

13

11

09

13

09

13

09

12

09

09

rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.

ORDERING INFORMATION

LNL= LED Night Light (50,000 hrs.) provided by Cooper

Specifications and Dimensions subject to change without notice.

ADC041578

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

03/29/2007 1:18:35 PM

Page 2
Image 2
Cooper Lighting FDI specifications Photometrics, Candlepower Distribution, Zonal Lumen Summary, Coefficient of Utilization