HALO LED H4 Series
The Halo H4 LED is a family of 4” aperture recessed downlight housings designed for use with Halo EL4 Series LED Light Engines and compatible 4” LED trims. Halo H4 LED housings have integral LED drivers that offer dimming as a standard feature.
H456ICAT120D is an insulated ceiling,
Catalog #
Project
Comments
Prepared by
HALO®
Type
Date
DESIGN FEATURES
MECHANICAL |
| installed without tools and |
| incandescent and magnetic low | ||
Housings |
| without removing knockouts. |
| voltage dimmers; and dims to 5% | ||
• | Accepts a wide range of |
| using dimmers with low end trim | |||
• | Box enclosure of formed |
| ||||
| aluminum construction. |
| • | adjustment. | ||
• | Openings are gasketed |
| cables - the standard cable types | Standard incandescent dimmers | ||
| used in lighting in both U.S. and |
| require a minimum load of | |||
|
|
|
| |||
|
| Canada. |
| typically over 40 watts on the | ||
• | Designed for insulated ceilings in |
|
| |||
| - Allows wiring connections to be |
| circuit for full range dimming | |||
| direct contact with insulation. |
|
| |||
|
| made outside the junction box |
| performance (four LED modules). | ||
| (May also be installed in |
|
| |||
|
| - Simply insert the cable directly | • | For dimming with digital (smart) | ||
|
| |||||
Plaster Frame |
| into the trap after connections |
| |||
| are made. |
| dimming fewer than four LED | |||
• | Galvanized steel |
| - Accommodates the following |
| modules, LED rated or electronic | |
| construction. |
|
| low voltage dimmers are required | ||
|
| standard |
| |||
• The housing can be removed from |
|
| (ELV dimmers need a neutral | |||
| cable sizes: |
| ||||
| plaster frame to provide access to |
|
| connection in the wallbox). | ||
|
| (US) #14/2, #14/3, #12/2, #12/3 |
| |||
| the junction box. |
| Labels | |||
|
| (Canada) #14/2, #14/3, #12/2 | ||||
• | Plaster frame features include: |
| ||||
| • | UL/cUL Listed 1598 Luminaire | ||||
LED Connection | ||||||
| - Patented regressed locking screw | |||||
| • | UL/cUL Listed for Damp Location | ||||
| positioned for securing hanger | • | LED connector is a | |||
| • | UL/cUL Listed for Wet Location, | ||||
| bars from below the ceiling. |
| connector offering easy installation | |||
|
|
| covered ceiling - with select trims | |||
| - Cutouts for easily crimping |
| with the EL4 Series LED Light |
| ||
|
| • | UL/cUL listed for Feed Through | |||
|
| Engine. | ||||
| hanger bars in position. |
| ||||
| • | LED connector meets California | • | UL/cUL listed for Direct Contact | ||
| - | |||||
|
|
| with insulation and combustible | |||
|
|
| ||||
|
| requirement for a |
| material | ||
| - HALO identity embossed on |
|
| |||
|
| base socket, and where required | Compliance | |||
| plaster frame. |
| ||||
|
| to qualify as a | • | Use with designated LED light | ||
GOT NAIL! Pass |
| |||||
| luminaire. |
| engines and trims for ENERGY | |||
Bar Hangers | LED Driver |
| STAR® qualification. | |||
• | • | LED dimmable driver mounts | • | Can be used for State of California | ||
| in regular lumber, engineered | |||||
|
| to the housing. |
| Title 24 high efficacy compliance | ||
| lumber and laminated beams. |
|
| |||
| • | Driver is a120 Volt, high efficiency, |
| with designated LED light engines | ||
• | Safety and guidance system |
| ||||
| electronic power supply providing |
| and trims. | |||
| prevents snagging, ensures |
|
| |||
|
| low voltage power to EL Series | • | Can be used for International | ||
| smooth straight nail penetration |
| ||||
|
| LED Light Engines. |
| Energy Conservation Code (IECC) | ||
| and allows bar hangers to be easily |
|
| |||
| • | Driver meets FCC EMI/RFI |
| high efficacy compliance with | ||
| removed if necessary. |
| ||||
|
| Consumer Level limits for use in |
| designated LED light engines | ||
• | Automatic leveling flange aligns |
|
| |||
| residential and commercial |
| and trims. | |||
| the housing and lets you hold the |
|
| |||
|
| installations. | • Refer to specification sheets online | |||
| housing in place with one hand |
| ||||
| • | Driver features high power factor |
| for compliance information. | ||
| while driving nails. |
| ||||
|
| and low THD and has integral | Qualification | |||
• | Housing can be positioned at any |
| ||||
| thermal protection in the event | IC and | ||||
| point within 24” joist span. |
| ||||
|
| of over temperature or internal | Certified under | |||
• |
| |||||
| failure. | |||||
| listed UL/cUL 1598. May be used to | |||||
| hangers to be shortened without |
| ||||
| • | Driver is specifically designed | ||||
| meet insulated ceiling and restricted | |||||
| removing from plaster frame. | |||||
|
| for compatibility with EL4 LED | ||||
• | Score lines allow “tooless” |
| ||||
| Light Engines, and operates the |
| • Washington State Energy Code | |||
| shortening for 12” joists. |
|
| |||
|
| LED for long life, meeting 50,000 |
| |||
|
|
| • International Energy | |||
• Bar hangers may be repositioned |
|
| ||||
| hour / 70% lumen maintenance |
| ||||
|
| Conservation Code (IECC) | ||||
| 90°. |
| standard. |
| ||
|
|
| • New York State Energy | |||
• | Integral | • | If dimming is not required the |
| ||
| Conservation Construction | |||||
|
| fixture can be operated from a |
| |||
|
|
| Code | |||
| required. |
| standard wall switch. |
| ||
|
|
| • State of California Title 24 | |||
| Dimming |
| ||||
| “Recessed Luminaires in | |||||
• Positioned to accommodate | • The HALO H4 LED luminaire is |
| ||||
| Insulated Ceilings.” | |||||
| straight conduit runs |
| dimmable to 15% with most |
| ||
|
|
|
| |||
• | Seven 1/2” trade size conduit |
| standard 120V dimmers; |
|
| |
| knockouts with true |
| including |
|
| |
• |
| electronic low voltage dimmers |
|
| ||
|
| (recommended); many |
|
|
www.cooperlighting.com
H456ICAT120D
Recessed Housing
New Construction
Insulated Ceiling -
With 4” LED Light Engines
and 4” LED Trims
High Efficacy LED Housing- Dimmable
F O R U S E I N I N S U L AT E D C E I L I N G S F O R D I R E C T C O N TAC T W I T H I N S U L AT I O N
A L S O S U I TA B L E F O R N O N - I C A P P L I C AT I O N S
H4 Series LED Energy Data:
(Values at
Sound Rating: Class A standards
Input Voltage: 120V
Power Factor: >0.90
Input Frequency: 50/60Hz
THD: <20%
Rated Wattage: 15W max.
Input Power: 14.0W
Input Current: 121mA
Driver Compliance: UL6950, LPS rated Maximum IC (Insulated Ceiling) Ambient Continuous Operating Room Temperature: 25°C (77°F)
Maximum
H4 Series LED
Summary Lighting Data:
Lumen range:. . . . . . .
Lumens per watt:. . . . . . up to 46
Color
Correlated Color Temperature
(CCT):. . . . . . . .
Color Rendering Index (CRI, Ra):. . 80
ADV110681
rev 4/8/11