HALO LED H4 Series

The Halo H4 LED is a family of 4” aperture recessed downlight housings designed for use with Halo EL4 Series LED Light Engines and compatible 4” LED trims. Halo H4 LED housings have integral LED drivers that offer dimming as a standard feature.

H456ICAT120D is an insulated ceiling, AIR-TITETMhousing offering 120 volt dimming capability with many incandescent or electronic low voltage dimmers. Designed for use with EL4 series LED Light Engines and TL4 LED Series Trims, the H456ICAT120D offers high quality downlighting along with high efficacy – the result being great lighting and significant energy savings.

Catalog #

Project

Comments

Prepared by

HALO®

Type

Date

DESIGN FEATURES

MECHANICAL

 

installed without tools and

 

incandescent and magnetic low

Housings

 

without removing knockouts.

 

voltage dimmers; and dims to 5%

Accepts a wide range of

 

using dimmers with low end trim

Box enclosure of formed

 

 

aluminum construction.

 

non-metallic (type NM) sheathed

adjustment.

Openings are gasketed

 

cables - the standard cable types

Standard incandescent dimmers

 

used in lighting in both U.S. and

 

require a minimum load of

 

AIR-TITE.

 

 

 

 

Canada.

 

typically over 40 watts on the

Designed for insulated ceilings in

 

 

 

- Allows wiring connections to be

 

circuit for full range dimming

 

direct contact with insulation.

 

 

 

 

made outside the junction box

 

performance (four LED modules).

 

(May also be installed in

 

 

 

 

- Simply insert the cable directly

For dimming with digital (smart)

 

non-insulated ceilings.)

 

Plaster Frame

 

into the trap after connections

 

multi-location dimmers or when

 

are made.

 

dimming fewer than four LED

Galvanized steel die-formed

 

- Accommodates the following

 

modules, LED rated or electronic

 

construction.

 

 

low voltage dimmers are required

 

 

standard non-metallic sheathed

 

• The housing can be removed from

 

 

(ELV dimmers need a neutral

 

cable sizes:

 

 

plaster frame to provide access to

 

 

connection in the wallbox).

 

 

(US) #14/2, #14/3, #12/2, #12/3

 

 

the junction box.

 

Labels

 

 

(Canada) #14/2, #14/3, #12/2

Plaster frame features include:

 

 

UL/cUL Listed 1598 Luminaire

LED Connection

 

- Patented regressed locking screw

 

UL/cUL Listed for Damp Location

 

positioned for securing hanger

LED connector is a non-screw base

 

UL/cUL Listed for Wet Location,

 

bars from below the ceiling.

 

connector offering easy installation

 

 

 

covered ceiling - with select trims

 

- Cutouts for easily crimping

 

with the EL4 Series LED Light

 

 

 

UL/cUL listed for Feed Through

 

 

Engine.

 

hanger bars in position.

 

 

LED connector meets California

UL/cUL listed for Direct Contact

 

- AIR-TITE aperture gasket is

 

 

Title-24 high-efficacy luminaire

 

with insulation and combustible

 

pre-installed.

 

 

 

 

requirement for a non-screw

 

material

 

- HALO identity embossed on

 

 

 

 

base socket, and where required

Compliance

 

plaster frame.

 

 

 

to qualify as a high-efficacy

Use with designated LED light

GOT NAIL! Pass -N-Thru™

 

 

luminaire.

 

engines and trims for ENERGY

Bar Hangers

LED Driver

 

STAR® qualification.

Pre-installed nail easily installs

LED dimmable driver mounts

Can be used for State of California

 

in regular lumber, engineered

 

 

to the housing.

 

Title 24 high efficacy compliance

 

lumber and laminated beams.

 

 

 

Driver is a120 Volt, high efficiency,

 

with designated LED light engines

Safety and guidance system

 

 

electronic power supply providing

 

and trims.

 

prevents snagging, ensures

 

 

 

 

low voltage power to EL Series

Can be used for International

 

smooth straight nail penetration

 

 

 

LED Light Engines.

 

Energy Conservation Code (IECC)

 

and allows bar hangers to be easily

 

 

 

Driver meets FCC EMI/RFI

 

high efficacy compliance with

 

removed if necessary.

 

 

 

Consumer Level limits for use in

 

designated LED light engines

Automatic leveling flange aligns

 

 

 

residential and commercial

 

and trims.

 

the housing and lets you hold the

 

 

 

 

installations.

• Refer to specification sheets online

 

housing in place with one hand

 

 

Driver features high power factor

 

for compliance information.

 

while driving nails.

 

 

 

and low THD and has integral

Qualification

Housing can be positioned at any

 

 

thermal protection in the event

IC and AIR-TITE™

 

point within 24” joist span.

 

 

 

of over temperature or internal

Certified under ASTM-E283 and

Pass-N-Thru™ feature allows bar

 

 

failure.

 

listed UL/cUL 1598. May be used to

 

hangers to be shortened without

 

 

Driver is specifically designed

 

meet insulated ceiling and restricted

 

removing from plaster frame.

 

 

for compatibility with EL4 LED

air-flow requirements such as:

Score lines allow “tooless”

 

 

Light Engines, and operates the

 

• Washington State Energy Code

 

shortening for 12” joists.

 

 

 

 

LED for long life, meeting 50,000

 

 

 

 

• International Energy

• Bar hangers may be repositioned

 

 

 

hour / 70% lumen maintenance

 

 

 

Conservation Code (IECC)

 

90°.

 

standard.

 

 

 

 

• New York State Energy

Integral T-bar clip snaps onto

If dimming is not required the

 

 

Conservation Construction

 

T-bars - no additional clips

 

fixture can be operated from a

 

 

 

 

Code (NY-ECCC)

 

required.

 

standard wall switch.

 

 

 

 

• State of California Title 24

Slide-N-Side™ Junction Box

Dimming

 

 

“Recessed Luminaires in

• Positioned to accommodate

• The HALO H4 LED luminaire is

 

 

Insulated Ceilings.”

 

straight conduit runs

 

dimmable to 15% with most

 

 

 

 

 

Seven 1/2” trade size conduit

 

standard 120V dimmers;

 

 

 

knockouts with true pry-out slots

 

including LED-rated and

 

 

Slide-N-Sidewire traps allow

 

electronic low voltage dimmers

 

 

 

non-metallic sheathed cable to be

 

(recommended); many

 

 

www.cooperlighting.com

H456ICAT120D

4-Inch LED

Recessed Housing

New Construction

Insulated Ceiling -

With 4” LED Light Engines

and 4” LED Trims

High Efficacy LED Housing- Dimmable

F O R U S E I N I N S U L AT E D C E I L I N G S F O R D I R E C T C O N TAC T W I T H I N S U L AT I O N

A L S O S U I TA B L E F O R N O N - I C A P P L I C AT I O N S

H4 Series LED Energy Data:

(Values at non-dimming line voltage.) Minimum Starting Temp: -30°C (-22°F) EMI/RFI: FCC Title 47 CFR, Part 18 (Consumer)

Sound Rating: Class A standards

Input Voltage: 120V

Power Factor: >0.90

Input Frequency: 50/60Hz

THD: <20%

Rated Wattage: 15W max.

Input Power: 14.0W

Input Current: 121mA

Driver Compliance: UL6950, LPS rated Maximum IC (Insulated Ceiling) Ambient Continuous Operating Room Temperature: 25°C (77°F)

Maximum Non-IC (Non-Insulated Ceiling) Ambient Continuous Operating Room Temperature: 40°C (104°F)

H4 Series LED

Summary Lighting Data:

Lumen range:. . . . . . . 534-700

Lumens per watt:. . . . . . up to 46

Color

Correlated Color Temperature

(CCT):. . . . . . . . 2700K-4000K

Color Rendering Index (CRI, Ra):. . 80

ADV110681

rev 4/8/11

Page 1
Image 1
Cooper Lighting H456ICAT120D specifications Halo LED H4 Series