COOPER LIGHTING - LUMARK®

D I M E N S I O N SD E S C R I P T I O N

INDUSTRIAL

Maximum Height is

16"=27 15/16" [710mm] 22"=30 7/16" [773mm] 25"=31 5/8" [803mm] See ordering information for details

16" [406mm]

22" [559mm] 25" [635mm]

The BenchMark HB prismatic high-bay utilizes a durable heavy-duty die-cast aluminum ballast housing and prismatic acrylic reflector for maximum durability and photometric performance. U.L. listed and CSA certified. Damp location standard.

The BenchMark HB prismatic high-bay is perfect for retail stores, wholesale warehouses, grocery chains, malls and auto showrooms.

P o w e r e d b y

HB

16", 22" & 25"

PRISMATIC BENCHMARK

t e c h n o l o g y

O R D E R I N G I N F O R M AT I O N

S A M P L E N U M B E R : H P H B - P D 1 6 - M - 2 5 0 - M T- Q

1 7 5 - 1 0 0 0 W

H i g h P r e s s u r e S o d i u m P u l s e S t a r t M e t a l M e t a l H a l i d e

H E A V Y- D U T Y P R I S M AT I C H I G H - B AY I N D U S T R I A L L U M I N A I R E

Lamp Type

Series

Refractor Type

HP=High

HB=High-Bay

PD=Prismatic

Pressure

BenchMark

Acrylic

Sodium 1

MH=Metal Halide 2

MP=Pulse Start MH (CWA) 2

ML=Pulse Start MH (Linear Reactor) 2, 3, 4

MD=Pulse Start Metal Halide (Electronic) 2, 5, 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refractor

Socket Position/

Lamp

Diameter

Distribution 7

Wattage

16=16"

 

 

C=Concentrated

175=175W

22=22"

 

 

M=Medium

200=200W

25=25"

 

 

W=Wide

250=250W

 

 

 

 

 

 

 

320=320W

 

 

 

 

 

 

 

350=350W

 

 

 

 

 

 

 

400=400W

 

 

 

 

 

 

 

450=450W

 

 

 

 

 

 

 

600=600W 8

 

 

 

 

 

 

 

750=750W

 

 

 

 

 

 

 

1000=1000W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage 9 120V 208V 6 240V 6 277V 6 347V 480V

MT=Multi-Tap 10 TT=Triple-Tap 11 5T=5-Tap 12 E=Electronic 6

Options &

Accessories 13

(See Pages 541-545)

• Easy slide-on die-cast

aluminum mounting box

with tapped opening for

3/4" conduit

• Durable heavy-duty

die-cast aluminum

housing for lasting

performance in the

harshest environments.

Integrally hinged for

ease of maintenance with

optional toolless entry.

Finished in a standard

white polyester powder

L A M P M O R T A L I T Y A N D L U M E N M A I N T E N A N C E C O M PA R I S O N S

paint

LAMP MORTALITY

 

100

 

90

 

80

Survival

70

60

% Lamp

50

40

 

30

 

20

10

0

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

20000

22000

24000

26000

28000

30000

 

 

 

 

 

 

 

Lamp Life [Hours]

 

 

 

 

 

 

 

 

Natural White TM & Uni-Form ® Pulse Start on ECON TECHNOLOGY

Uni-Form®Pulse Start on CWA

 

Probe Start Metal Halide on CWA

NOTE: Lamp Mortality and Lumen Maintenance Charts Courtesy of VENTURE®

LUMEN MAINTENANCE

 

100

 

 

 

 

 

 

 

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

% Lumens

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

20000

Lamp Life [Hours]

90% Mean Lumens Nat-Wt-ECON

86% Mean Lumens-UPS-ECON

 

75% Mean Lumens-UPS CWA

 

 

65% Mean Lumens-Probe Start

 

 

• High power factor ballast

with class H insulation.

ECONTM electronic

ballast technology

delivers longer lamp life

and improved lumen

output while maintaining

a constant lamp wattage.

Minimum starting

temperature is -40°C

(-40°F) for HPS and

-30°C (-20°F) for MH

• Universal ladder brackets

allow for the flexibility to

change out with other

reflectors / refractors

available in aluminum or

Refractor

Lamp

Ambient

Supply

Type

Wattage

Environment

Wire (Min.)

PD16

175-400W

40°C (ECON)*

105°C

 

 

PD22

175-450W

55°C (Open) or

PD25

400-1000W

40°C (Enclosed)**

 

 

 

NOTES: * Electronic Pulse Start Metal Halide.

**PD16 enclosed is 250W only. PD25 enclosed is 400W only.

NOTES: 1 Not available in 175, 200, 320, 350, 450 and 750W. 2 Approved lamp containment barrier required when enclosed rated MP/ML/MH lamps are used. 2005 NEC code requires that open luminaires must utilize a safety glass bottom (SGB) accessory or an Open rated socket (OR) and lamp. 3 175, 200, 250, 320, 350 & 400W only. 4 277V only, not available with HSW, HL or HC options. 5 “MD” option available on PD22 and PD25 with 250, 320, 350 or 400W Pulse Start Metal Halide only. 6 MD available in 208, 240 or 277V or with “E” option which will operate voltages from 200-277V 50/60 Hz. 7 Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the nomenclature of the fixture. 8 HPS only. 9 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 10 Multi-tap ballast 120/208/240/277V wired 277V. 11 Triple-tap ballast 120/277/347V wired 347V. 12 5-tap ballast 120/208/240/277/480V wired 480V. 13 Add as suffix in the order shown. 14 Specifications and dimensions subject to change without notice.

 

glass

Mogul-base porcelain

 

socket

Easily mounted prismatic

 

acrylic refractor has

 

multiple field-adjustable

 

distribution patterns for

 

precision control

Approximate net weight:

 

37 lbs. (17 kgs.)

COOPER LIGHTING

527

Page 1
Image 1
Cooper Lighting HB 16, HB 22, HB 25 dimensions Lamp Mortality, Lumen Maintenance