Cooper Lighting HVL dimensions P H O T O M E T R I C S

Models: HVL

1 4
Download 4 pages 12.59 Kb
Page 4
Image 4
P H O T O M E T R I C S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H V L S I N G L E 8 ” L I N E A R

P H O T O M E T R I C S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

 

 

 

 

 

 

Candela

 

 

 

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

Angle

Along II

45°

Across

 

rc

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

0

259

259

259

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

10

253

251

252

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

229

233

238

 

 

81

81

81

81

79

79

79

79

75

75

75

71

71

71

67

67

67

65

 

0

30

187

213

227

 

 

72

68

64

61

70

66

63

60

62

60

57

59

57

55

56

54

52

51

1

40

140

190

214

 

65

58

53

48

63

57

52

47

54

49

46

51

47

44

48

45

43

41

 

2

50

101

163

200

 

 

59

51

44

39

57

49

44

39

47

42

38

44

40

37

42

38

35

34

3

60

67

136

179

 

54

45

38

33

52

43

37

33

41

36

32

39

35

31

37

33

30

28

 

4

70

35

103

150

 

 

49

40

33

28

47

39

33

28

37

31

27

35

30

27

33

29

26

24

 

5

80

7

80

150

 

 

45

36

29

24

44

35

29

24

33

28

24

32

27

23

30

26

23

21

 

6

90

0

35

82

 

 

42

32

26

21

41

32

26

21

30

25

21

29

24

20

28

23

20

19

HVL8-117-UNV-C-EB81-S

7

100

0

13

37

 

39

29

23

19

38

29

23

19

28

22

19

26

22

18

25

21

18

16

8

110

0

6

16

Electronic Ballast

 

37

27

21

17

35

26

21

17

25

20

17

24

20

16

23

19

16

15

9

120

0

3

7

 

 

34

25

19

15

33

24

19

15

23

18

15

23

18

15

22

18

15

13

(1) F17T8/TL841 Lamp

10

130

0

1

3

1300 Lumens

Zonal Lumen Summary

 

 

Typical VCP Percentages

 

 

 

140

0

0

2

Spacing criterion:

 

 

 

 

 

150

1

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height Along

Height Across

160

1

1

0

(II) 1.1 x mounting

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

Lumens

%Lamp

%Fixture

 

Room Size (Ft.)

 

8.5’

10.0’

8.5’

10.0’

170

1

1

1

height, () 1.3 x

 

 

0-30

 

196

 

15.0

 

21.8

 

20 x 20

 

 

69

77

48

59

180

1

1

1

mounting height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-40

 

319

 

24.6

 

35.7

 

30 x 30

 

 

61

66

36

45

 

 

 

 

Efficiency 68.9%

0-60

 

581

 

44.7

 

64.8

 

30 x 60

 

 

62

66

25

29

 

 

 

 

Test Report

0-90

 

850

 

65.4

 

94.9

 

60 x 30

 

 

54

60

42

50

 

 

 

 

90-180

 

46

 

3.5

 

5.1

 

60 x 60

 

 

53

56

28

32

 

 

 

 

242p108

 

 

 

 

 

 

 

 

 

 

0-180

 

896

 

68.9

 

100.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.04

HVL8-217-UNV-O-EB81-S

Electronic Ballast

(2) F17T8/TL841 Lamp

1300 Lumens ea.

Coefficients of Utilization

 

Effective floor cavity reflectance

 

20%

 

 

 

 

 

 

 

 

rc

 

80%

 

 

70%

 

 

50%

 

 

30%

 

 

10%

 

0%

rw

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

59

59

59

59

57

57

57

57

54

54

54

52

52

52

49

49

49

48

1

53

50

48

46

51

49

47

45

47

45

43

44

43

42

42

41

40

39

2

48

44

40

37

46

43

39

36

40

38

35

39

36

34

37

35

33

32

3

44

38

34

30

42

37

33

30

35

32

29

34

31

29

32

30

28

27

4

40

34

29

26

39

33

29

25

31

28

25

30

27

24

29

26

24

23

5

37

30

25

22

35

29

25

22

28

24

21

27

24

21

26

23

21

20

6

34

27

22

19

33

26

22

19

25

22

19

24

21

18

23

20

18

17

7

31

24

20

17

30

24

20

17

23

19

16

22

19

16

21

18

16

15

8

29

22

18

15

28

22

18

15

21

17

15

20

17

15

20

17

14

13

9

27

20

16

13

26

20

16

13

19

16

13

19

15

13

18

15

13

12

10

25

19

15

12

25

18

15

12

18

14

12

17

14

12

17

14

12

11

Candela

Angle

Along II

45°

Across

0

405

405

405

10

399

399

399

20

378

379

381

30

344

347

351

40

298

304

310

50

242

251

260

60

179

190

204

70

109

128

148

80

40

73

97

90

0

34

56

100

0

12

28

110

0

4

12

120

0

3

6

130

0

2

4

140

1

1

2

Spacing criterion:

(II)1.3 x mounting height, () 1.3 x

mounting height

Efficiency 49.6%

Test Report 242p105

Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.04

Zonal Lumen Summary

Zone

Lumens

%Lamp

%Fixture

0-30

317

12.2

24.6

0-40

522

20.1

40.4

0-60

935

35.9

72.4

0-90

1250

48.1

96.8

90-180

41

1.6

3.2

0-180

1291

49.6

100.0

Typical VCP Percentages

 

Height Along

Height Across

Room Size (Ft.)

8.5’

10.0’

8.5’

10.0’

20 x 20

53

61

48

57

30 x 30

47

51

41

46

30 x 60

43

46

33

37

60 x 30

49

52

45

49

60 x 60

43

45

36

38

150

1

1

2

160

1

1

1

170

2

2

2

180

2

2

2

N O T E S : See option/accessories or technical sections for additional detailed product data. Specifications and Dimensions subject to change without notice.

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 Fax 770.486.4801 ADC050453

Page 4
Image 4
Cooper Lighting HVL dimensions P H O T O M E T R I C S