INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
Talon Large
Sheet 1 of 3
7/23/08IMI-682SW
WARNING: Risk of Fire/Electric Shock. If not qualified, consult an electrician.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.
WARNING: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components to their recommended torque values.
WARNING: Risk of Fire/Electrical Shock. Upside down installation can result in overheating or accumulation of water in fixture. Install right side up.
Tools Required Socket, 5/16" Socket, 3/4" Deep Well Socket, Electrical wiring tools.
NOTE: These luminaires are designed for outdoor lighting services, and |
|
|
should not be used in area of limited ventilation or in high ambient |
|
|
temperature enclosures. Construction is suitable for down lighting only. |
|
|
Best results will be obtained if installed and maintained according to the |
|
|
following recommendations. |
| Latches |
1. With the fixture on its back, open and remove door by pressing thumb |
|
|
latches outward at the same time, open the door and lift it from the | FIG. 1 |
|
hinges. FIG. 1 |
| |
|
| |
2. Run the two (2) threaded rods through the center of the |
|
|
hole details in the arm extrusion. To help orient the arm correctly with |
|
|
the housing, please note that one end of the extruded arm has an angled |
|
|
cut and the other has a perpendicular cut with two (2) drain notches |
|
|
located on the bottom. If assembling to a round pole, use the round pole |
|
|
adapter with the drain channels located at the extruded arm end with |
|
|
the drain slots. Mate the angled side of the extruded arm to the housing | Nut Plate |
|
so that the bottom surface of the extrusion is parallel to the bottom of |
| |
Fits Inside | Round Pole Adapter (Optional) | |
the fixture, and the drain notches are facing down and located away | Of Pole | |
|
| |
from the housing. FIG. 2 Slide the threaded rods into the interior of the |
| Arm |
|
| |
housing. Attach flat washer, lock washer, and nut into place in the order |
|
|
shown in FIG. 2. Torque hex nuts to 450 lb/in. | FIG. 2 |
|
3. If necessary, remove the cap on the pole. Position the housing and arm |
| |
to assemble it to the pole. Lower the nut plate into the interior of the | Mounting Rod (2) | |
pole as shown. Slide the threaded rods through the pole and thread into |
| |
the nut plate until the rod protrudes though the nut plate slightly. Tighten | Hardware: Washer, | |
both nuts located inside of the housing to 30 lb/ft of torque. | Lock Washer, And | |
Hex Nut | ||
|
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
NOTE: Specifications and dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADW081603