Cooper Lighting IMI-687 Sheet 2 of, Installation Instructions, Talon Medium

Models: IMI-687

1 3
Download 3 pages 7.31 Kb
Page 2
Image 2
Sheet 2 of 3

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.

Talon Medium

Sheet 2 of 3

11/29/07IMI-687

WARNING: Risk of Fire/Electric Shock. If not qualified, consult an electrician.

WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.

WARNING: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.

WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components to their recommended torque values.

WARNING: Risk of Fire/Electrical Shock. Upside down installation can result in overheating or accumulation of water in fixture. Install right side up.

5.With the pole and fixture(s) raised into position, place the power tray onto the hinges of the housing electrical compartment and let

it hang free. Locate the power connector plug and rotate the power tray until the connection can be made with the mating connector in the housing. Raise the powertray until the two wing screws engage and tighten until fully snug.

6.Replace door on the hinges at the rear of the housing, rotate into position, and assure that both latches are fastened securely.

FIXTURE MAINTENANCE

RELAMPING

1.Disengage both latches and open the door. Do not let the door swing freely on the hinges.

2.Replace the lamp with the appropriate type and wattage and reassemble the refractor to the upper housing. FIG. 3

3.Close the door and assure that the latches are securely fastened.

PLUG-IN STARTER REPLACEMENT

This procedure applies to fixtures with a plug-in type starter. Disengage both latches and open the door. Do not let the door swing freely on the hinges. Loosen the power tray thumb screws, unplug the power connector as you lower the powertray, and continue lowering until the powertray hangs free on the hinges. The starter is located in the position shown. Remove and replace. Reverse the directions to secure the powertray and the door after starter replacement.

FIG. 3

Powertray Manual background

Thumbscrews (2)

FIG. 5

FIG. 4

Plug-In Starter

1.Remove the plug-in starter from the receptacle and replace. FIG. 4 and FIG. 5

2.Assure that the wing screws on the powertray and both latches on the door are fastened securely.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH071363

Page 2
Image 2
Cooper Lighting IMI-687 installation instructions Sheet 2 of, Installation Instructions, Talon Medium