INSTALLATION INSTRUCTIONS
|
| |
| COMBOLIGHT | |
Avoid Fire or Electric Shock | | | |||
R | TRIMLESS | ||||
|
|
|
| Page 1 of 3 | |
*Installation Instructions for qualified electricians only. |
|
|
| THIS PRODUCT MUST BE INSTALLED IN | |
|
|
| ACCORDANCE WITH THE APPLICABLE | ||
*Install per National Electrical Code and local regulations. |
|
|
| INSTALLATION CODE BY A PERSON | |
*Read Installation Instructions completely before installation. |
|
|
| FAMILIAR WITH THE CONSTRUCTION AND | |
*Failure to follow Installation Instructions may void warranties. |
|
|
| OPERATION OF THE PRODUCT AND THE | |
|
|
|
| HAZARDS INVOLVED. |
FIXTURE MOUNTING:
1.First remove TRIMLESS INSERT from Housing by pulling straight out.
See Fig 1. Fixture must be mounted using either BUTTERFLY MOUNTING BRACKETS or HANGER BARS (Contact RSA Dealer for HANGER BARS).
HOUSING
JBOX | SCREW | |
JBOX COVER | ||
|
|
| Figure 3 | ||
Figure 1 | TRIMLESS INSERT | CEILING MATERIAL INSTALLATION: |
| |
|
| |||
| 8. A clean, square hole in the CEILING MATERIAL must be cut. Install the | |||
INSTALLATION NOTE: |
| |||
| ceiling material below housing as seen in Fig 4. | |||
|
| |||
DO NOT install insulation within 3in of any part of the Luminaire. | 9. Replace the TRIMLESS INSERT into the HOUSING by pushing until flush | |||
with the CEILING MATERIAL as seen in Fig 4. Using the OUTER | ||||
Blinking light of this thermally protected Luminaire may indicate overheating. | ||||
ALIGNMENT HOLES on the TRIMLESS INSERT, screw the TRIMLESS | ||||
|
| |||
BUTTERFLY MOUNTING: |
| INSERT into the HOUSING using DRYWALL SCREWS into the Outer | ||
| Holes on the TRIMLESS INSERT. |
| ||
|
|
| ||
2. Fixture comes equipped with universal BUTTERFLY MOUNTING | 10. Smooth out MUDDING COMPOUND / TAPE from around aperture to | |||
surrounding areas of DRYWALL as seen in Fig 4. | ||||
BRACKETS that can take common 1" or | ||||
MOUNTING CHANNELS (supplied by others). See Fig 2. |
| OUTER ALIGNMENT HOLES | ||
|
|
| ||
3. Position fixture so the MOUNTING CHANNELS lie on top of the ceiling |
|
| ||
runners. |
|
|
| |
4. Fasten MOUNTING CHANNELS securely to ceiling runners. |
|
| ||
5. Secure MOUNTING CHANNELS to universal BUTTERFLY MOUNTING |
|
| ||
BRACKETS with wire tie downs. |
|
|
| |
6. The BUTTERFLY MOUNTING BRACKETS are |
|
| ||
should be set so that the APERTURE COLLAR will be flush with the |
|
| ||
finished ceiling plane. |
|
|
| |
MOUNTING |
|
| OUTER ALIGNMENT HOLES | |
CHANNEL |
|
| ||
BUTTERFLY |
|
|
| |
MOUNTING |
|
|
| |
BRACKET | HEX |
|
| |
|
|
| ||
| SCREW |
|
| |
| APERTURE |
| HOUSING | |
Figure 2 | COLLAR |
| DRYWALL SCREW | |
|
| |||
ELECTRICAL: |
|
|
| |
7. Remove the JBOX COVER from the JBOX by removing the four SCREWS. | TRIMLESS | DRYWALL | ||
Connect supply lead wires to junction box lead wires in accordance with | INSERT | MUDDING | ||
your local electrical code(s) or N.E.C. Replace JBOX COVER onto JBOX, | Figure 4 | COMPOUND | ||
securing with SCREWS. See Fig 3. |
|
|