F L O O D L I G H T I N G T E R M I N O L O G Y

F L O O D L I G H T I N G T E R M I N O L O G Y

-Floodlighting Terminology

-NEMA [IES] Classifications

F L O O D L I G H T I N G T E R M I N O L O G Y

Ever wonder how NEMA (H x V) Classifications are derived, or how they relate to the performance and design application of a floodlighting distribution? How about beam and field angles, and maximum candela values?

-Maximum Candela is defined as the maximum candela value emitted from the luminaire in any given direction.

-Beam angle is defined as the included angle between points of 50% of Maximum Candela.

-Field Angle is defined as the included angle between points of 10% of Maximum Candela.

As an example, a distribution with a 50,000 Cd maximum candela value

as shown in the intensity distribution graph to the right (FIG. 1) would have a Beam Angle defined by the included angle of 25,000 Cd values, and a Field Angle defined by the included angle of 5,000 Cd values.

E X A M P L E

Max Candela = 50,000 Cd

Candela Value defining Beam Angle = (50% * 50,000 Cd) = 25,000 Cd Candela Value defining Field Angle = (10% * 50,000 Cd) = 5,000 Cd Beam Angle = 90°

Field Angle = 120°

N E M A [ I E S ] C L A S S I F I C A T I O N S

FIG. 1

90°

80°

70°

60°

50°

45°

40°

30°

20°

10°

5

 

 

 

 

d

 

 

 

 

 

,000 c

Field

 

Angle

 

 

10,000 cd

 

 

 

15,

000 cd

 

 

 

20,

00

0 cd

25

 

0 cd

,00

Beam

Angle

30

 

0 cd

,00

 

 

 

35

,000 cd

 

 

 

 

 

c

4

0,000

d

 

 

 

cd

4

5,000

5

 

 

c d

0,000

 

 

 

0°

 

20°

10°

90°

80°

70°

60°

50°

45°

40°

30°

NEMA classifications are extrapolated from the table below and are determined by a distribution’s Field Angle. This relative classification is used to describe the general shape and application of a distribution. NEMA classifications are used to classify both the horizontal and vertical components of a floodlight distribution.

The example distribution in FIG. 1 above would have a NEMA Classification of 6 as the 120° Field Angle falls between the 100-130° range.

NEMA Beam

Field Angle

Description +

Classification

Range

Setback

1

10-18°

Narrowest Beam, Long Setback

 

 

 

2

18-29°

Narrow Beam, Long Setback

 

 

 

3

29-46°

Narrow Beam, Long Setback

 

 

 

4

46-70°

Medium Beam, Medium Setback

 

 

 

5

70-100°

Medium Beam, Medium Setback

 

 

 

6

100-130°

Wide Beam, Shorter Setback

 

 

 

7

130°-Greater

Widest Beam, Short Setback

 

 

 

4