Cooper Lighting Vision Flood O R D E R I N G I N F O R M A T I O N, D I M E N S I O N S, Black

Models: Vision Flood

1 24
Download 24 pages 21.38 Kb
Page 23
Image 23
O R D E R I N G I N F O R M A T I O N

O R D E R I N G I N F O R M A T I O N

Sample Number: VFM-K-400-MH-MT-MF-GM-L

Product Family

VFS=Vision Flood

Small

VFM=Vision Flood

Medium

Mounting

Type

K=Knuckle

Lamp Wattage 1 50=50W 70=70W

100=100W

150=150W

175=175W

250=250W

320=320W 2

350=350W 2

400=400W

750=750W 3

1000=1000W 3

Lamp Type

MH=Metal Halide

MP=Pulse Start

Metal Halide

HPS=High Pressure

Sodium

Voltage 4

120=120V

208=208V

240=240V

277=277V

347=347V

480=480V DT=Dual-Tap

wired 277V 5 MT=Multi-Tap

wired 277V 5

TT=Triple-Tap wired 347V 5

Distribution

NS=Narrow Spot

NF=Narrow Flood

MF=Medium Flood

WF=Wide Flood

VF=Vertical Flood

HS=Horizontal Spot

Colors

(add as suffix/must specify) 6 BK=Black

AP=Grey BZ=Bronze WH=White DP=Dark Platinum GM=Graphite Metallic

Options (add as suffix) F=Single Fuse

(120, 277, or 347V) Specify Voltage FF=Double Fuse

(208, 240 or 480V) Specify Voltage Q=Quartz Restrike 7

EM=Quartz Restrike with Delay (Also Strikes at Cold Start) 7

EM/SC=Quartz Emergency Separate Circuit 7

PC=Button Type Photocontrol (Specify Voltage) L=Lamp Included

Accessories

(order separately, replace XX with color suffix)

VFSJB-XX=Architectural J-Box SM-XX=Stanchion Mount

ST-XX=Stanchion Mount Tenon WM-XX=Wall Mount WMA-XX=Wall Mount Arm WMT-XX=Wall Mount Arm Tenon Mount TMA-XX=Twin Mount Arm—EPA 0.35

TMT-XX=Twin Mount Arm Tenon Mount—EPA 0.42 SF-XX=Slipfitter

PM1-XX=Post Mount Extension Single—EPA 0.12 PM2-XX=Post Mount Extension Double—EPA 0.12 SMT-XX=Surface Mount Tenon VFS-BD-XX=Barn Doors—EPA 1.01 VFS-TV-XX=Top Visor—EPA 0.6 VFS-VS=Vandal Shield

VFS-CFR-XX=Color Filter Adapter with Red Gel VFS-CFB-XX=Color Filter Adapter with Bright Blue Gel VFS-CFG-XX=Color Filter Adapter with Deep Green Gel VFS-CFO-XX=Color Filter Adapter with Warm Orange Gel

VFM

NOTE: 1 All lamps are mogul-base on VFM fixtures and medium-base on VFS. 2 320/350W Pulse Start Metal Halide lamps only.

3 Metal Halide only, requires reduced envelope BT or ED37 lamp. 4 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 5 Dual-Tap is 120/277V wired 277V. Multi-Tap is 120/208/240/277V wired 277V. Triple-Tap ballast is 120/277/347V wired 347V. 6 RAL and custom color matches available. Consult your INVUE Lighting Systems Representative for more information. 7 Quartz options available on VFM only.

D I M E N S I O N S

 

Vision Flood Small [VFS]

Vision Flood Medium [VFM]

SMT-XX=Surface Mount Tenon

ST-XX=Stanchion Mount Tenon TMT-XX=Twin Mount Arm Tenon Mount—EPA 0.42 WMT-XX=Wall Mount Arm Tenon Mount VFM-BD-XX=Barn Doors

VFM-TV-XX=Top Visor VFM-4S-XX=4-Sided Shield VFM-VS=Vandal Shield VFM-GL=External Grid Louvers

VFM-CFR-XX=Color Filter Adapter with Red Gel VFM-CFB-XX=Color Filter Adapter with Bright Blue Gel VFM-CFG-XX=Color Filter Adapter with Deep Green Gel VFM-CFO-XX=Color Filter Adapter with Warm Orange Gel

10"

[254 mm]

X

7 1/2"

D I M E N S I O N S14" [356 mm] W A T T A G E T A B L ES H I P P I N G D A T A X=2 15/16" [191 mm] [75 mm]

16 1/2"

[419 mm]

7 11/16"

[196 mm]

23" [584 mm]

S T A N D A R D C O L O R S11 13/64" [284 mm] BlackGrey

W A T T A G E T A B L ES H I P P I N G D A T A

 

VFS

VFM

Metal Halide

50, 70, 100, 175W

175, 250, 400, 1000W

Pulse Start Metal Halide

 

250, 320, 350, 400, 750W

High Pressure Sodium

50, 70, 100, 150W

150, 250, 400W

 

VFS

VFM

Net. Weight (lbs.)

37

53

E.P.A. (lbs.)

1.19

3.24

NOTE: The above are approximate weights.

S T A N D A R D C O L O R S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

AP

 

BZ

WH

DP

GM

Black

Grey

 

Bronze

White

Dark Platinum

Graphite Metallic

A P P L I C A T I O N S D E P A R T M E N T

Let the application experts at Cooper Lighting design your next lighting layout. Aided by the latest computer simulation software and a comprehensive lighting background, our Application Engineers can design, analyze, and provide statistical layouts for any lighting application. Whether the design criteria calls for Illuminance, Luminance, or Small Target Visibility (STV) compliance, Cooper Lighting can provide the fixture layout and supporting documentation necessary to help secure your next project.

I N V U E W E B S I T E

Visit invuelighting.com for the latest product information from INVUE Lighting Systems. With instant access to IES photometric files, PDF product specification sheets, new product announcements, and other helpful specification tools, the INVUE Lighting website is an invaluable resource for getting information to customers-quickly.

22

V I S I O N F L O O D A r c h i t e c t u r a l F l o o d L u m i n a i r e

Page 23
Image 23
Cooper Lighting O R D E R I N G I N F O R M A T I O N, D I M E N S I O N S, Vision Flood Small VFS, Black, Grey, Bronze