Cooper Lighting Vision Wall installation instructions Installation Instructions, Sheet 4 of

Models: Vision Wall

1 2
Download 2 pages 58.09 Kb
Page 1
Image 1
INSTALLATION INSTRUCTIONS

TM

 

INSTALLATION INSTRUCTIONS

VISION WALL

 

 

Sheet 4 of 4

 

 

 

 

 

 

 

IMPORTANT: Read carefully before installing fixture. Retain for future reference.

12/29/03

IMI-498

 

 

 

 

 

WARNING: Make certain power is OFF before starting installation or attempting any maintenance.

Adjustment Of Light Throw

Your Vision Wall luminaire has an adjustable forward light throw.

TM

 

 

 

VISION WALL

INSTALLATION INSTRUCTIONS

Sheet 1 of 4

 

 

 

 

 

 

 

 

IMPORTANT: Read carefully before installing fixture. Retain for future reference.

 

12/29/03

IMI-498

 

 

General: Upon receipt of fixture thoroughly inspect for any

Safety: This fixture must be wired in accordance with

freight damage, which should be brought to the attention of

the national electrical code and applicable local codes

the delivery carrier. Compare the catalog description listed

and ordinance. Proper grounding is required to insure

on the packing slip with the fixture label on the housing to

personal safety. Carefully observe grounding procedure

assure you have received the correct merchandise.

under installation section. All work should be done by a

 

qualified electrician.

 

 

1. Obtain a 3/16" allen wrench.

Adjustment Screw

WARNING: Make certain power is OFF before starting installation or attempting any maintenance.

2. Locate the stainless steel button head screw on the outside of the fixture (See Fig. 4).

3. Turn the screw clockwise to pivot the reflector and throw the light forward.

4. You may monitor the reflector rotation by viewing the

Fig. 4

bottom edge of the reflector and the indicator located

 

inside the fixture. This is viewable through the glass

 

(See Fig. 5).

 

5. Rotating the screw counter-clockwise brings the reflector back down to zero.

Degree Indicator

Fig. 5

CAUTION:

Prior to installing lamp in the fixture, verify that lamp source and wattage correspond with the fixture label. Lamp should be screwed securely into the socket. Do not over tighten.

WARNING:

Recheck to be sure that the fixture has been wired properly. Improper wiring may result in ballast failure which voids all warranties.

Cleaning

Your Vision Wall Luminaire has three different types of mounting interface:

1.Standard Mount—mounts to any standard 4" J-box. (Included with every fixture) (See Fig. 1).

2.Embedded Mount—mounts to a plate embedded into

the wall (Optional Accessory VWM/EM) (See Fig. 2).

3. Thru Way Box—mounts to surface mounted casting, allowing a conduit run (Optional Accessory VWM/TB) (See Fig. 3).

NOTE:

Please refer to your mounting kit for specific instructions.

Conduit run by others

4" J Box (By Others)

Standard Mount Kit

screws to J Box

Embedded Mount Kit

Fig. 2

EMBEDDED MOUNT

VWM/EM

Thru Way Mounting

The reflector and door glass may be cleaned with any suitable non-abrasive glass cleaning solution, soap, or detergent and rinse with clean water. The reflectors efficiency will be retained only if cleaned at regular intervals. Clean with mild soap or detergent and water, or liquid wax emulsion. The refractor should also be cleaned along with the reflector, using care not to chip glass surfaces.

CAUTION:

Do not use abrasive, strong alkaline or acid cleaners.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 AVU033142

Fig. 1

Fig. 3

STANDARD MOUNT

THRU-WAY BOX

 

VWM/TB

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

AVU033142