![INSTALLATION INSTRUCTIONS](/images/new-backgrounds/73200/732001x1.webp)
Replacing GIB Controller on Quest Juice Dispensers
INSTALLATION INSTRUCTIONS
REPLACING GIB CONTROLLER ON QUEST JUICE DISPENSERS
Parts and Tools
Parts List
Kit should include: 1 each of the following
GIBC Field Kit
1440000902 Control Ice Bank 120/60 QST/SLJ/UN750/VG245/VNT
2440000907 P- Housing Elect Plug A GIBC
3440000908 P- Housing Elect Plug B GIBC
4440000909 P- Housing Elect Plug C GIBC
5440000910 P- Housing Elect Plug D GIBC
6 | 440000919 | P- Cover “A” |
7 | 440000920 | P- Cover “B” |
8 | 440000921 | P- Cover “C” |
9 | 440000922 | P- Cover “D” |
Tools Required
One - Phillips Screw Driver
Wiring Diagram of GIB Control
If housing and plugs are damaged during disassembly please refer to the drawing below to for proper location of inputs and outputs and wires. Each plug is keyed for proper placement.
440000902
WATER BATH AGITATION MOTOR
INPUT POWER
1
REFRIGERATION
PUMP MOTOR
ICE CONTROL PROBE
2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 11 12 |
| A | B |
|
| C | D |
| Black |
|
|
|
| Yellow |
| White |
|
|
|
| Orange |
| Green (GND) |
|
|
|
| Purple |
| Tan | Blue | Yellow/Green (GND) | Black | White Green (GND) |
|
| 440000907 |
|
|
|
| 440000910 |
| 440000919 |
|
|
|
| |
|
|
|
|
| 440000922 | |
|
|
|
|
|
| |
| Connetcor Key |
|
|
|
|
|
| 440000908 |
|
|
| 440000909 |
|
| 440000920 |
|
|
|
| |
|
|
|
| 440000921 |
| |
|
|
|
|
|
| |
Release Date: March 18, 2003 | www.cornelius.com | Revision: A | ||||
© 2003, IMI Cornelius Inc. |
|
| - 1 - |
| Publication Number: 729011138INS |