Cornelius ED 300 BN Removal and Replacement of Agitators, Agitator Removal and Replacement

Models: ED 300 BN

1 17
Download 17 pages 54.9 Kb
Page 11
Image 11

 

LEFT HAND

RIGHT HAND AGITATOR

 

WITH HOLE IN UPRIGHT

 

AGITATOR

 

 

 

 

O-RING

COUNTER

 

CLOCKWISE

CLOCKWISE

 

ROTATION

 

ROTATION

 

FRONT (VALVE SIDE) VIEW FROM TOP OF DISPENSER

FIGURE 7. AGITATOR REMOVAL AND REPLACEMENT

REMOVAL AND REPLACEMENT OF AGITATORS

Remove agitators for cleaning as follows:

1.Lift agitator and disc from Dispenser.

2.Remove O-Ring, starting at notch. Warm the O-ring with water to ease removal.

3.Lift the plastic agitator disk off of the stainless steel agitator.

4.Grip agitator at the center and pull up.

5.To replace, reverse steps.

NOTE: Refer to Sanitize Procedure in the Owner’s Instruction for complete cleaning and sanitizing in- structions.