INSTALLATION INSTRUCTIONS
IMPORTANT: It is the responsibility of the Installer to ensure that the water supply to the dispensing equipment is provided with protection against backflow by an air gap as defined in ANSI/ASME A112
Water pipe connections directly connected to a potable water supply shall be sized, installed, and maintained according to Federal, State, and local codes.
All drain connections must be installed with adequate backflow protection to prevent contamination of the potable water supply and the ice storage hopper in accordance with Federal, State, and local codes.
1.Locate the Dispenser indoors on a level countertop. The Dispenser must be sealed to the countertop. Us- ing the mounting template (see Figure 3), determine the outline of the Dispenser and the six mounting holes for the desired location of the Dispenser. Remove the (6) plastic hole plugs from the threaded base mounting holes, the two base black plastic panels, and the two rear stainless steel cabinet access panels. Apply a continuous bead of NSF International (NSF) listed silastic sealant (Dow Corning 732 or equal) around the outline of the Dispenser on the countertop. Position the Dispenser on the countertop and wipe away any excess sealant immediately. Bolt the Dispenser to the countertop with
2.The beverage and water manifold inlet lines, ice storage hopper drain tubes (2), and electrical power cord are routed through the two large openings in the base of the Dispenser. Access for these
3.Connect the (2) hopper drain tubes to an approved drain system with a backflow preventer in compliance to the local plumbing code. Do not “tee”into the drip tray drain line.
4.DRIP TRAY DRAIN ASSEMBLY: Route the drain tube to an open drain with the end of the tube above the “flood”level of the drain. Use the tubing, fittings, clamps, and insulation provided with the Dispenser to assemble the drain. The completed drain line must pitch continuously downward and contain no “traps”or improper drainage will result.
5.BEVERAGE SYSTEM: Connect the beverage system product lines to the Dispenser. Consult the water manifold
6.Replace the two rear stainless steel cabinet panels after completing the
7.Clean the ice storage hopper interior (see CLEANING INSTRUCTIONS in the Owner’s manual).
8.Connect the power cord to a 120 VAC, 60 Hz
620913202 | 2 |