Cornelius TJ90-ABC, TJ45-AB manual Service And Maintenance, Adjustments, Gate Restrictor Plate

Models: TJ45-A TJ90-ABC TJ90-AB TJ90-A TJ45-AB

1 21
Download 21 pages 45.03 Kb
Page 8
Image 8
SERVICE AND MAINTENANCE

SERVICE AND MAINTENANCE

CAUTION: Disconnect power to dispenser before installing, removing or adjusting this kit.

INSTALL PLATE ON

STUDS AS SHOWN

FIGURE 2. GATE RESTRICTOR PLATE

ADJUSTMENTS

This dispenser is provided with a gate restrictor plate, installed in it highest position. This plate adjusts the rate of ice flow from the dispenser. In applications using buckets, carafes or other large containers, the plate may be removed entirely for maximum ice flow. For glasses and cups, the plate may be adjusted downward to reduce the flow of ice. The best position depends on the type of ice being used and the size container and must be found by trial and error. Adjustment is made by loosening the upper two ice chute retaining nuts, sliding the re- strictor plate to the desired position and re-tightening the nuts.

90632

6

Page 8
Image 8
Cornelius TJ90-ABC, TJ45-AB manual Service And Maintenance, Adjustments, Gate Restrictor Plate