Cornelius UC100 Set Up Supplied Air Compressor, Dispenser, Drain Line, Drain Point, Horizontal

Models: UC100

1 10
Download 10 pages 14.58 Kb
Page 5
Image 5
Dispenser

UC100 Installation Manual

3.The dispenser drain lines must slope a minimum of 1/4” per foot to the floor drain, see FIGURE 2. Drain lines must be installed to comply with federal, state and local codes. It is required to fully insulate all drain lines and fittings to prevent condensation from forming!!!

Dispenser

Drain Line

Drain Point

 

 

Horizontal

 

 

 

 

Reference Line

 

 

 

1/4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain Line 1’Drain Point

Floor DrainHorizontal1/4”

FIGURE 2

If the unit is installed in a: 36” tall counter top, the floor drain must be within 23’ of the dispenser. 34” tall counter top, the floor drain must be within 15’ of the dispenser. 30” tall counter top, the floor drain must be within 1’ of the dispenser.

4.Clean the hopper interior (see CLEANING INSTRUCTIONS in Operator’s Manual).

5.Connect the power cord to a 120 volt, 60 cycle, 15–Amp, 3–wire grounded receptacle.

Set Up Supplied Air Compressor

1.Set up and install the air compressor, follow the manufacturer’s installation instructions.

2.Route the 1/4” beverage tube from the air compressor to the air valve solenoid inlet tube connector on the dispenser.

NOTE: The filter/regulator is preset to 50 psi and should not require adjustment.

FILTER/REGULATOR ASSEMBLY

PRESET TO 50 PSI, NO ADJUSTMENT NEEDED

E-BOX

AIR VALVE SOLENOID

CLEAR TUBE

CUSTOMER CONNECTION

INCOMING SUPPLY SHOULD BE

SET TO 100 PSI

AIR CYLINDER

(LOCATED IN

TOWER CLADDING)

1/4" TUBE WHIP

(SUPPLIED WITH UNIT) CLEAR RED TUBE

AIR SCHEMATIC

FIGURE 3

© 2008, IMI Cornelius Inc.

- 5 -

Publication Number: 621054211INS

Page 5
Image 5