INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door, at a minimum height of 5 feet (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided. For

pre-wired installations (as in new home construction), it may be mounted to a single gang box (Figure 2).

1.Strip 7/16" (11 mm) of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color: white wire to 2 and white/red wire to the 1.

2.Door Control Button: Fasten securely with 6ABx1-1/2" screws.

Console Model: Remove cover by gently prying along one side with a screwdriver (Figure 1). Fasten with 6ABx1-1/4" self-tapping screws (drywall installation) or

6-32x1" machine screws (into gang box) as follows:

Install bottom screw, allowing 1/8" (3 mm) to protrude above wall surface.

Position bottom of door control on screw head and slide down to secure. Adjust screw for snug fit.

Drill and install top screw with care to avoid cracking plastic housing. Do not overtighten.

Insert top tabs and snap on cover.

3.(For standard installation only) Run bell wire up wall and across ceiling to motor unit. Use insulated staples to secure wire in several places. Do not pierce wire with a staple, creating a short or open circuit.

4.Strip 7/16" (11 mm) of insulation from end of bell wire. Connect bell wire to the quick-connect terminals as follows: white to white and white/red to red.

NOTE: When connecting multiple door controls to the opener, twist same color wires together. Insert wires into quick-connect holes: white to white and red/white to red.

5. Position the antenna wire as shown.

WARNING

To prevent possible SERIOUS INJURY or DEATH from electrocution:

Be sure power is not connected BEFORE installing door control.

Connect ONLY to 24 VOLT low voltage wires.

To prevent possible SERIOUS INJURY or DEATH from a closing garage door:

Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m), and away from all moving parts of door.

NEVER permit children to operate or play with door control push buttons or remote control transmitters.

Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.

ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.

Outside Keylock Accessory Connections

To opener quick-connect terminals: white to white; white/red to red.

 

 

 

HARDWARE SHOWN

Screw 6ABx1-1/2"

 

 

ACTUAL SIZE

 

 

 

Door Control Button

 

 

 

Screw 6ABx1-1/4"

 

 

Insulated

Control Console (std installation)

Staples

Screw 6-32x1"

 

 

 

Control Console (pre-wired)

 

Drywall Anchors

Figure 1

 

Figure 2

REMOVE & REPLACE COVER

PRE-WIRED

INSTALLATION

To Replace,

 

To Remove,

 

Insert

 

Twist

 

 

Top Tabs

 

 

Here

 

 

First

 

 

 

 

 

6.Use tacks or staples to permanently attach entrapment warning label to wall near door control, and manual release/safety reverse test label in

a prominent location on inside of garage door.

NOTE: DO NOT connect power and operate opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.

 

 

 

24 Volt

 

 

 

2-Conductor

 

 

 

Bell Wire

Lighted

Quick-Connect

DOOR CONTROL

Push Button

2-Conductor Terminals

BUTTON (BACK VIEW)

 

Bell Wire

 

 

 

 

WHT

 

 

2

 

 

 

1

D

 

 

RE

 

 

Bell

 

 

 

 

 

 

Wire

DOOR

 

CONTROL

STANDARD

BUTTON

CONTROL CONSOLE

 

Door Control

To release wire, push in

Connections

tab with screwdriver tip

Strip wire 7/16" (11 mm)

7/16" (11 mm)

Red White Grey

Terminal Screws

STANDARD CONTROL (BACK VIEW)

Top

Mounting

Hole

WHITE RED

2 1 Terminal

Screws

Antenna

Bottom

Bell Mounting

WireHole

17