INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door, at a minimum height of 5 feet (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided. For
1.Strip 7/16" (11 mm) of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color: white wire to 2 and white/red wire to the 1.
2.Door Control Button: Fasten securely withConsole Model: Remove cover by gently prying along one side with a screwdriver (Figure 1). Fasten with
•Install bottom screw, allowing 1/8" (3 mm) to protrude above wall surface.
•Position bottom of door control on screw head and slide down to secure. Adjust screw for snug fit.
•Drill and install top screw with care to avoid cracking plastic housing. Do not overtighten.
•Insert top tabs and snap on cover.
3.(For standard installation only) Run bell wire up wall and across ceiling to motor unit. Use insulated staples to secure wire in several places. Do not pierce wire with a staple, creating a short or open circuit.
4.Strip 7/16" (11 mm) of insulation from end of bell wire. Connect bell wire to the
NOTE: When connecting multiple door controls to the opener, twist same color wires together. Insert wires into
5. Position the antenna wire as shown.
WARNING
To prevent possible SERIOUS INJURY or DEATH from electrocution:
•Be sure power is not connected BEFORE installing door control.
•Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
•Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m), and away from all moving parts of door.
•NEVER permit children to operate or play with door control push buttons or remote control transmitters.
•Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
•ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.
Outside Keylock Accessory ConnectionsTo opener
|
|
| HARDWARE SHOWN | |
Screw |
|
| ACTUAL SIZE | |
|
|
| ||
Door Control Button |
|
|
| |
Screw |
|
| Insulated | |
Control Console (std installation) | Staples | |||
Screw |
|
|
| |
Control Console |
| Drywall Anchors | ||
Figure 1 |
| Figure 2 | ||
REMOVE & REPLACE COVER | ||||
INSTALLATION | ||||
To Replace, |
| |||
To Remove, |
| |||
Insert |
| |||
Twist |
|
| ||
Top Tabs |
|
| ||
Here |
|
| ||
First |
|
| ||
|
|
|
6.Use tacks or staples to permanently attach entrapment warning label to wall near door control, and manual release/safety reverse test label in
a prominent location on inside of garage door.
NOTE: DO NOT connect power and operate opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.
|
|
| 24 Volt |
|
|
| |
|
|
| Bell Wire |
Lighted | DOOR CONTROL | ||
Push Button | BUTTON (BACK VIEW) | ||
| Bell Wire |
|
|
|
| WHT | |
|
| 2 |
|
|
| 1 | D |
|
| RE | |
|
| Bell | |
|
|
| |
|
|
| Wire |
DOOR |
| |
CONTROL | STANDARD | |
BUTTON | ||
CONTROL CONSOLE | ||
|
Door Control | To release wire, push in |
Connections | tab with screwdriver tip |
Strip wire 7/16" (11 mm)
7/16" (11 mm)
Red White Grey
Terminal Screws
STANDARD CONTROL (BACK VIEW)
Top
Mounting
Hole
WHITE RED
2 1 Terminal
Screws
Antenna
Bottom
Bell Mounting
WireHole
17