GFX-1200H Amplifier

GFX-1200H TECHNICAL SPECIFICATIONS

Output Power Rating

 

70 watts RMS @ 5% THD 8 ohms load 120VAC

 

 

100 watts RMS @ 5% THD 4 ohms load 120VAC

 

 

Maximum Input Signal Level Accepted

8 volts, peak-to-peak

 

 

 

Total System Gain

 

Overdrive Channel: 110dB all controls @10, Gain 2; 88dB Gain 1

 

 

Clean Channel: 58dB all controls @10

 

 

 

Input Impedance

 

470k ohms

Overdrive Channel:

Low Control:

11dB Range @ 80Hz

 

Shape Control:

Proprietary Circuit

 

High Control:

10dB Range @ 10kHz

 

 

 

Clean Channel:

Low Control:

22dB Range @ 80Hz

 

Mid Control:

14dB Range @ 600Hz

 

High Control:

28dB Range @ 10kHz

 

 

Input Power Requirements

120 VAC, 60Hz, 230VA

 

 

100/115VAC, 50/60Hz, 230VA

 

 

230VAC, 50/60Hz, 230VA

 

 

Cabinet Size and Weight:

9-3/8” H x 19-3/4” W x 9-1/2” D, 25 lbs.

 

 

 

The GFX-1200H is covered with a durable black Tolex material: wipe it clean with a lint-free cloth. Never spray cleaning agents onto the cabinet. Avoid abrasive cleansers which could damage the finish.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER.

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

ATTENTION

RISQUE D'ELECTROCUTION

NE PAS OUVRIR

ATTENTION: POUR REDUIRE D'ELECTROCUTION NE PAS

ENLEVER LE COUVERCLE. AUCUNE PIECE INTERNE N'EST REPRABLE

PAR L'UTILISATEUR. POUR TOUTE REPARATION, S'ADRESSER A UN

TECHNICIEN QUALIFIE.

VORSICHT

ELEKTRISCHE SCHLAGGEFAHR

NICHT OFFENEN

VORSICHT: ZUR MINIMIERUNG ELEKTRISCHER SCHLAGGEFAHR NICHT

DEN DECKEL ABENHMEN. INTERNE TEILE KONNEN NICHT VOM

BENUTZER GEWARTET WERDEN. DIE WARTUNG IS QUALIFIZIERTEM

WARTUNGSPERSONAL ZU UBERLASSEN.

THIS EQUIPMENT HAS BEEN DESIGNED AND ENGINEERED TO PROVIDE SAFE AND RELIABLE OPERATION. IN ORDER TO PROLONG THE LIFE OF THE UNIT AND PREVENT ACCIDENTAL DAMAGES OR INJURY, PLEASE FOLLOW THESE PRECAUTIONARY GUIDELINES:

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN CHASSIS; DO NOT DEFEAT OR REMOVE THE GROUND PIN OF THE POWER CORD; CONNECT ONLY TO A PROPERLY GROUNDED AC POWER OUTLET.

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.

CAUTION: NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

CAUTION: OUR AMPLIFIERS ARE CAPABLE OF PRODUCING HIGH SOUND PRESSURE LEVELS. CONTINUED EXPOSURE TO HIGH SOUND PRESSURE LEVELS CAN CAUSE PERMANENT HEARING IMPAIRMENT OR LOSS. USER CAUTION IS ADVISED AND EAR PROTECTION IS RECOMMENDED IF UNIT IS OPERATED AT HIGH VOLUME.

EXPLANATION OF GRAPHICAL SYMBOLS:

"DANGEROUS VOLTAGE"

EXPLICACION DE SIMBOLOS GRAFICOS:

= “VOLTAJE PELIGROSO”

EXPLICATION DES SYMBÔLES GRAPHIQUES:

"DANGER HAUTE TENSION"

"GEFAHLICHE SPANNUNG"

"IT IS NECESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL"

=“ES NECESARIO QUE EL USUARIO SE REFIERA AL MANUAL DE INSTRUCCIONES.” "REFERREZ-VOUS AU MANUAL D'UTILISATION"

"UNBEDINGT IN DER BEDIENUNGSANLEITUNG NACHSCHLAGEN"

Crate continually develops new products, as well as improves existing ones. For this reason, the

specifications and information in this Crate manual are subject to change without notice.

©1998 SLM ELECTRONICS, A DIVISION OF ST. LOUIS MUSIC, 1400 FERGUSON, ST. LOUIS, MO. 63133

P/N 47-477-03 • 08/98

Page 4
Image 4
Crate Amplifiers owner manual GFX-1200H Technical Specifications