Installation and Operating Instructions
TPR II Wall Mounted Panel
Convector Heaters
Dimensions (mm)
Model(s) | Part number | Watt | A | B |
| ||||
750 | 620 | 108 | ||
1000 | 620 | 108 | ||
1250 | 688 | 108 | ||
1500 | 688 | 108 | ||
2000 | 860 | 108 |
Fig 1
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following:
IMPORTANT - The wall brackets supplied with the appliance must be used.
IMPORTANT - If the heater is installed in a room containing a bath or shower, it must be so installed that switches and other controls cannot be touched by a person using a bath or shower.
Do not use outdoors.
Do not locate the heater immediately below a fixed socket outlet or connection box.
Do not cover the heater. Do not place material or garments on the heater, or obstruct the air circulation around the heater, for instance by curtains or pushing furniture up against the heater, as this could cause overheating and a fire risk.
NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet slots in the base of the heater.
The heater must not be covered.
WARNING
This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance.
Note that due care and consideration must be taken when using this heater in series with a thermal control, a program controller, a timer or any other device that switches on the heat automatically, since a fire risk exists when the heater is accidentally covered or displaced.
If the supply cord is damaged it must be replaced by the manufacturer or service agent or a similarly qualified person in order to avoid a hazard.
Electrical
The electrical installation must be carried out by a competent electrician, and be in strict accordance with the current I.E.E. regulations for Electrical Equipment in Buildings.
The heater is fitted with a length of flexible cable type
A means for disconnection in all poles must be provided in the fixed wiring in accordance with the wiring rules.
Supplementary Earth Bonding
Should Equipotential Earth Bonding be required, the earthing conductor in the supply cord is deemed to provide the supplementary bonding connection (see Regulation 547-
General
The TPR Convector is designed for wall mounting on the wall brackets supplied. It should only be operated when in the upright position as shown.
All models are protected to IP24 standard.
Models TPR2....W are fitted with a thermostat only.
Models TPR2….TW are fitted with a thermostat and a 24 hour timer.
Before connecting the heater, check that the supply voltage is the same as that stated on the heater.